PubMed · 10367444

An electrically isolated balanced wideband current source: basic considerations and design.

Abstract

At relatively high frequencies, the application of an alternating current through the body or a body segment results in electromagnetic stray fields which reduce the amount of current actually injected into the tissue under study. This radiation effect can be reduced by use of a symmetrical configuration current source. The symmetry of such an arrangement, however, depends on the stray capacitances of the source with respect to surrounding equipment. To minimise these effects, it is required that the source is electrically isolated from the surrounding equipment and the subject under study. In this manner stray capacitances with respect to elements of the current source are reduced. In such a configuration common mode voltages to the input amplifier of the measuring system are also reduced. The paper describes design considerations and the implementation of a wideband current source capable of injecting alternating current in the order of 300 microARMS into biological tissue having impedances up to 1 k omega. Current stabilisation is obtained by means of a control circuit which measures the actual current passing through the tissue under study. Leakage currents arising from shielding and stray capacitances are compensated for. The usable frequency range is between 4 kHz and 1024 kHz and current stability is better than 0.2%. Through the use of a symmetrical, floating circuit a configuration is obtained which substantially reduces stray effects. The current source is connected to other circuits by means of two isolation ports: (1) a transformer coupling for the carrier frequency; and (2) an opto-coupler to transfer a phase reference signal obtained from current measurement. The current amplitude can be modulated by controlling the reference input to the control loop by means of a third auxiliary isolation port for transfer of the modulating signal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H G Goovaerts, T J Faes, E Raaijmakers, R M Heethaar. 1998. An electrically isolated balanced wideband current source: basic considerations and design.. https://doi.org/10.1007/bf02524430

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cardiopulmonary monitoring at home: the CHIME monitor.

A new physiologic monitor for use in the home has been developed and used for the Collaborative Home Infant Monitor Evaluation (CHIME). This monitor measures infant breathing by respiratory inductance plethysmography and transthoracic impedance; infant electrocardiogram, heart rate and R-R interval; haemoglobin O2 saturation of arterial blood at the periphery and sleep position. Monitor signals from a representative sample of 24 subjects from the CHIME database were of sufficient quality to be clinically interpreted 91.7% of the time for the respiratory inductance plethysmograph, 100% for the ECG, 99.7% for the heart rate and 87% for the 16 subjects of the 24 who used the pulse oximeter. The monitor detected breaths with a sensitivity of 96% and a specificity of 65% compared to human scorers. It detected all clinically significant bradycardias but identified an additional 737 events where a human scorer did not detect bradycardia. The monitor was considered to be superior to conventional monitors and, therefore, suitable for the successful conduct of the CHIME study.

Cardiography, Impedance↗

Pediatric impedance cardiography: temporal stability and intertask consistency.

The pathogenic processes responsible for cardiovascular disease have their origins in childhood. Although children's measures of heart rate and blood pressure have been found to be reliable, the reliability of impedance cardiography derived measures have not been evaluated. Thirty-three children, ages 8-11 participated in two sessions. Stressors included serial subtraction, isometric handgrip, and mirror-image tracing. Results indicated the impedance measures showed moderately high temporal stability (average scores r(avg) = .74; difference scores r(avg) = .53) and intertask consistency (average scores r(avg)= .78; difference scores r(avg)= .53). Blood pressure demonstrated the lowest reliability; Heather index, preejection period, and stroke volume demonstrated the highest. These findings suggest children's cardiovascular reactivity to laboratory stressors can be reliably and consistently assessed using impedance cardiography.

Cardiography, Impedance↗

Plethysmography: the new wave in haemodynamic monitoring--a review of clinical applications.

The plethysmograph, a useful, non-invasive circulatory assessment capability featured on most modern pulse oximeters, provides a waveform representation of pulsatile peripheral blood flow, from which can be drawn assessments of both the peripheral and central circulation. Implementation and maintenance of plethysmography monitoring is straightforward and uncomplicated by virtue of its non-invasiveness. Yet despite its capabilities, ease of use and widespread availability it remains an underutilised data source. Diagnostic and monitoring capabilities of the device include heart rate and rhythm monitoring, detection of myocardial and valvular dysfunction, assessment of intra-aortic balloon pump performance when pressure waveforms are unobtainable, detection and measurement of pulsus paradoxus, improved performance of the Allen's test and detection of peripheral vascular diseases, peripheral vasoconstriction and developing shock. This paper describes the range of established applications of plethysmography, reviews pertinent literature and describes the directions in which, in the absence of supportive literature, clinical practice is finding applications.

Cardiography, Impedance↗