PubMed Health⌕ Search

PubMed · 10369118

Multiple regression analysis of interference effects from a hemoglobin-based oxygen carrier solution.

Abstract

The use of hemoglobin-based oxygen carrier solutions in patients requiring blood transfusion will necessitate that clinical laboratories have mechanisms in place to evaluate the potential interference effect of these substances on testing methods. Because these oxygen carrier solutions contain acellular hemoglobin, but do not contain many of the intracellular enzymes and ions present in erythrocytes, interference effects from blood substitutes may be quite different when compared to in vivo or in vitro lysis of erythrocytes. We evaluated the potential interference effect of Diaspirin Cross-linked Hemoglobin on 29 different clinical laboratory analytes. Various combinations of these analytes were tested using the Hitachi 747 and 911 systems, a Beckman CX3, an Abbott AxSym, a Bayer Immuno I, and a Dade ACA IV; a total of 60 analyte/instrument combinations. We used the method of multiple regression analysis to classify interferences as analyte-dependent, analyte-independent, or a combination of the first two types. The presence of clinically significant test interference was derived by using the criteria for maximum allowable error specified in the Clinical Laboratory Improvement Amendments of 1988. Using these criteria, we found significant interference from Diaspirin Cross-linked Hemoglobin with 13 of 29 analytes tested. Interference was noted with the Hitachi 747 and 911 methods for albumin, alkaline phosphatase, total and conjugated bilirubin, cholesterol, total carbon dioxide, iron, lactate dehydrogenase, magnesium, total protein, and triglyceride. In addition, Diaspirin Cross-linked Hemoglobin interfered with measurement of L-lactate using the ACA IV and minor interference was noted with glucose measured using the Beckman CX3. Data from the interference studies was graphically displayed in the form of interference plots. These plots show the maximum allowable test error, due to Diaspirin Cross-linked Hemoglobin, as a function of analyte and interferent concentrations. Evaluation of the potential interference effect of hemoglobin-based oxygen carrier solutions with use of multiple regression analysis and graphical display of the resultant data in the form of interference plots allows for more reliable reporting of test results from specimens containing these products.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Kazmierczak, P G Catrou, A E Best, S W Sullivan, K P Briley. 1999. Multiple regression analysis of interference effects from a hemoglobin-based oxygen carrier solution.. https://doi.org/10.1515/cclm.1999.074

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid desensitization protocols for patients with cardiovascular disease and aspirin hypersensitivity in an era of dual antiplatelet therapy.

OBJECTIVE: To review the available protocols for rapid desensitization of patients with aspirin hypersensitivity and apply the data for use in patients with cardiovascular disease who would benefit from the dual antiplatelet therapy. DATA SOURCES: A literature search was conducted via MEDLINE from 1966 to December 2006. Main search terms included: aspirin sensitivity, aspirin allergy, aspirin desensitization, aspirin-induced asthma, aspirin therapy, and aspirin intolerance syndrome. STUDY SELECTION AND DATA EXTRACTION: Articles describing rapid aspirin desensitization protocols were selected for review. Literature pertaining to aspirin hypersensitivity, drug desensitization, and the use of aspirin and dual antiplatelet therapy was also examined. Three rapid desensitization protocols were identified and evaluated. DATA SYNTHESIS: While landmark studies demonstrated that dual antiplatelet therapy with aspirin and clopidogrel significantly reduces mortality and morbidity in acute coronary syndromes and coronary stenting, patients with aspirin hypersensitivity are frequently managed with clopidogrel alone with no supporting data. Approximately 10% of the population experiences hypersensitivity to aspirin, which can manifest as asthma exacerbations, rhinorrhea, angioedema, urticaria, and anaphylaxis. The hypersensitivity reaction is mediated through aspirin-directed antibodies or by excessive leukotriene production. The desensitization process involved depletion of these mediators, as well as down-regulation of leukotriene receptors. Two groups of investigators developed rapid protocols to desensitize patients with aspirin hypersensitivity safely and effectively. The rapid protocol developed by Wong provides benefits over other protocols with its low starting dose and completion in less than 3 hours, low incidence of adverse effects, and high success rate in aspirin desensitization. CONCLUSIONS: The Wong protocol is an attractive option for the rapid desensitization of patients requiring dual antiplatelet therapy with aspirin and clopidogrel in the perimyocardial infarction period.

Aspirin↗