Plastic migration from implanted central venous access devices.

Abstract

BACKGROUND: This is the first reported study of histologically confirmed migration from intravenous access devices in children. METHODS: The capsules from around intravenous access devices were examined by light microscopy to determine the extent of the foreign body response; energy dispersive x ray analysis was performed to document the elemental content of the foreign material. RESULTS: A fibroconnective tissue capsule was found around all the samples. Elemental silicon was found in six of 13 tissue samples, and a foreign body giant cell reaction was seen in three of these. CONCLUSIONS: The pseudocapsule that surrounds an implanted vascular access device often has residual foreign material, including silicone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P A Dewan, S K Condron, P N Morreau, R W Byard, J Terlet. 1999. Plastic migration from implanted central venous access devices.. https://doi.org/10.1136/adc.81.1.71

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Malposition of central venous catheters in hospitalized patients].

BACKGROUND: At the time of inserting a central catheter, it is recommended to check that its distal tip is positioned outside the heart cavities. Our objective was to determine the degree of fulfillment of this recommendation. PATIENTS AND METHOD: Cross-sectional study on patients carrying a central venous catheter who were admitted to conventional areas of a university hospital. We considered as "risk catheter" any catheter whose distal tip was located within the cardiac cavities. RESULTS: 34 out of 362 hospitalized patients had a central venous catheter. Fifty per cent of them were found to have a "risk catheter". In spite of its X-ray confirmation, no patient underwent a subsequent modification of the distal tip position. CONCLUSIONS: We have noticed a high percentage of patients with central venous catheters whose insertion supposed a cardiovascular risk. Unawareness of the serious complications that may arise from this fact probably justifies a high prevalence of misplacements.

Catheterization, Central Venous↗

Evaluation of the FASTSTART mode for reducing start-up delay in syringe pump infusion systems.

OBJECTIVE: The aim of the study was to evaluate the IVAC P7000 FASTSTART mode with regard to start-up performance in a 50-ml infusion syringe at a flow rate of 1 ml.h-1. METHODS: The time from depression of the start button to first fluid flow (T1) and to establishment of a pre-set flow rate (T2) were gravimetrically recorded with and without FASTSTART and with and without priming of the infusion system with a 1-ml fluid bolus prior to connection of the infusion line to the patient. RESULTS: FASTSTART significantly reduced start-up times in the unprimed syringe pump infusion system from (mean [SD]) 9.4 (6.0) to 2.5 (3.5) min for T1 and from 21.8 (9.8) to 9.4 (6.2) min for T2 (all p < 0.001). The greatest improvement in shortening of T1 and T2 was obtained when the system was primed prior to starting (p < 0.0001). After priming the infusion system, FASTSTART shortened T2 by some 50% from 1.4 (1.4) to 0.7 (0.6) min. CONCLUSION: Our data indicate that the FASTSTART procedure is effective and that substantial improvements can be obtained by priming the system prior to starting.

Catheterization, Central Venous↗