PubMed Health⌕ Search

PubMed · 10377796

[BOLD functional MRI: practical pitfalls].

Abstract

There is mounting criticism regarding the validity of blood oxygenation level dependent contrast functional magnetic resonance imaging (BOLD-fMRI) studies. The main sources of error in BOLD-fMRI are pixel misalignment and physiological noise. One of the widely practiced tactics to ameliorate motion related fictitious activation is post-processing motion correction algorithms. Nevertheless, the validity of activation data following application of such algorithms has not been totally confirmed. In this article, the practical pitfalls of BOLD-fMRI and potential correction algorithms are concisely discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Nakada. 1999. [BOLD functional MRI: practical pitfalls].. https://pubmed.ncbi.nlm.nih.gov/10377796/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Shared k-space echo planar imaging with keyhole.

Time-dependent phenomena are of great interest, and researchers have sought to shed light on these processes with MRI, particularly in vivo. In this work, a new hybrid technique based on EPI and using the concept of keyhole imaging is presented. By sharing peripheral k-space data between images and acquiring the keyhole more frequently, it is shown that the spatial resolution of the reconstructed images can be maintained. The method affords a higher temporal resolution and is more robust against susceptibility and chemical-shift artifacts than single-shot EPI. The method, termed shared k-space echo planar imaging with keyhole (shared EPIK), has been implemented on a standard clinical scanner. Technical details, simulation results, phantom images, in vivo images, and fMRI results are presented. These results indicate that the new method is robust and may be used for dynamic MRI applications. Magn Reson Med 45:109-117, 2001.

Artifacts↗

Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can be executed on a complete 3D data set within a single time of repetition cycle. In this study, a method to evaluate motion and realign functional images in real time implemented on standard imaging hardware is introduced. The detection of activity in correlation maps is improved, and artifactual edge enhancements are reduced. As the estimation of large movements is stable, this algorithm is attractive for clinical studies with uncooperative patients. Magn Reson Med 45:167-171, 2001.

Artifacts↗