PubMed Health⌕ Search

PubMed · 10388580

Transforming NMR data despite missing points.

Abstract

Some NMR experiments produce data with several of the initial points missing. The inverse discrete Fourier transform (IDFT) assumes these points are present so the data cannot be so transformed without artifact-ridden results. This problem is often particularly severe when projection imaging with free-induction decays (FIDs). This paper compares recent methods for obtaining a projection from incomplete data and elaborates on their strengths and limitations. One method is to write the transform that would take the desired projection to the truncated data set, and then solve the matrix equation by singular value decomposition. A second replaces the missing data with zeros, so that an IDFT produces a projection with unwanted artifacts. Then one solves the matrix equation that takes the desired projection to the artifact-ridden projection. A third uses the same artifact-ridden projection, but fits the region outside the bandwidth of the sample with as many sinusoidal functions as there are missing data. The coefficients of these functions are estimates of the missing data, and the projection is obtained by transforming the completed FID or subtracting the extrapolation of the fitted curve from the region containing the object. We show that when all three methods are applicable, they theoretically produce the same result. They differ by ease of implementation and possibly by computational errors. They give a result similar to that of the previous method that iteratively corrects the FID and projection after repeated IDFTs and DFTs. We find that one can obtain a projection despite missing a substantial number of data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D O Kuethe, A Caprihan, I J Lowe, D P Madio, H M Gach. 1999. Transforming NMR data despite missing points.. https://doi.org/10.1006/jmre.1999.1767

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

The cell in absence of aggregation artifacts.

Eduard Kellenberger understood that the conventional resin-embedding, he helped to develop (Ryter, A., Kellenberger, E., 1958. L'inclusion au polyester pour l'ultramicrotomie. J. Ultrastruct. Res. , 2, 200-214), was prone to aggregation artifacts (Kellenberger, E., 1987. The response to biological macromolecules and supramolecular structures to the physics of specimen cryo-preparation. In: Steinbrecht, R.A., Zierold, K. (Eds.), Cryo-techniques in Biological Electron Microscopy, Springer, Berlin, pp. 35-63). He was instrumental in developing various methods to overcome this limitation, for instance, by using low temperature-embedding and partially hydrophilic resins (Carlemalm, E., Garavito, R.M., Villiger, W., 1982. Resin development for electron microscopy and an analysis of embedding at low temperature. J. Microstruct., 126, 123-143; Villiger,W., 1993. Low temperature-embedding with Lowicryl resins. In: Robards, A.W., Wilson, A.J. (Eds.), Procedures in electron microscopy, Wiley, Chichester, UK, pp. 16:7.3-16:7.6). In principle, cryo-electron microscopy of vitreous sections is free of any aggregation artifact since the material remains fully hydrated and is free of chemical fixation or staining. The method is technically difficult still, but recent progress has made it amenable to routine practical applications. We compare here electron microscopical aspects of Zea mays meristem cells prepared by: (1) conventional resin-embedding and sectioning; (2) low temperature-embedding and sectioning of freeze substituted samples; and (3) cryo-sections of vitrified samples. The appearance of the extra-cellular space, the cytoplasm and the nucleoplasm are very different in conditions (1) and (3). They appear as compact, irregular and well delineated structures in conventional resin sections, whereas they are more diffuse and homogeneous in the vitreous sections. In the resin sections, the material seems to form a complex matrix, whereas it looks more like a thick soup in the vitreous sample. Low temperature-embedding (condition 2) shows an intermediate appearance. We suggest that regardless of the difference due to staining and different sectioning conditions, the other image differences are the consequence of aggregation artifacts in the resin-embedded specimens.

Artifacts↗

Potential pitfall in parathyroid sestamibi imaging resulting from a cardiac pacemaker.

A 47-year-old woman with a history of end-stage renal disease and hyperparathyroidism after total parathyroidectomy had Tc-99m sestamibi imaging to identify possible ectopic parathyroid tissue. This study was prompted by increasing calcium and parathyroid hormone levels after several years of taking calcium supplements necessitated by a surgically induced hypoparathyroid state and end-stage renal disease. The scan showed persistent linear activity in the upper right mediastinum in delayed images, after washout of the thyroid had occurred. Because of the unusual configuration of this finding, investigation of the patient's clinical history and other imaging studies was undertaken. The authors concluded that the unusual mediastinal uptake was not hyperactive parathyroid tissue, but rather was attributed to the presence of central venous pacemaker wires. Thus, this case illustrates a potential pitfall in parathyroid sestamibi imaging, the uptake of which may increase in the presence of a cardiac pacemaker, and it emphasizes the importance of correlative imaging.

Artifacts↗