A simple multi-specimen apparatus for fixed stress fatigue testing.

Abstract

To cope with the time-consuming characteristics of fatigue tests, a multi-specimen fatigue testing apparatus, which could test 10 specimens at a time, was designed, constructed, and tested. The specimens are fixed around a rotating axis, and the required stresses are applied by weights attached on the other end of each specimen. The test mode can be categorized as a stress-controlled flexural fatigue test. Its performance was tested by comparing it with a commercial three-point bending fatigue testing apparatus. The stress versus number of cycles to failure curves of poly(methylmethacrylate) (PMMA), which were obtained from both fatigue testing equipment, showed results that were similar to each other. The fatigue test results of acrylic bone cement in a fixed-stress mode also showed good agreement between the data obtained from the new apparatus and the commercial apparatus. The test results seem quite reliable and show feasibility of significantly reducing the overall test periods. It may be valuable, especially for the fatigue tests, which must be done with a low frequency and a low applied stress level such as a fatigue test of bone cements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Y Kim, T R Marrero, H K Yasuda, O A Pringle. 1999. A simple multi-specimen apparatus for fixed stress fatigue testing.. https://doi.org/10.1002/(sici)1097-4636(1999)48%3A3%3C297%3A%3Aaid-jbm13%3E3.0.co%3B2-h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Gamma-radiation-induced changes in structure and properties of tetracalcium phosphate and its derived calcium phosphate cement.

The purpose of the present study was to investigate the gamma-radiation effect on the structure and properties of the single-phase tetracalcium phosphate (TTCP) powder and its derived calcium phosphate cement (CPC). Experimental results show that low-dosed (0-30 kGy) CPC has a setting time of 10-12 min, while high-dosed (40-120 kGy) CPC has a setting time of 8-10 min. The low dose gamma-radiation does not significantly change porosity volume fraction or compressive strength of the CPC. The pH values of all CPC samples fell in a relatively narrow band, with a band width of 8.5-9.1 (in terms of pH value). With a dose of 10 or 20 kGy gamma-radiation, the TTCP-apatite conversion ratio does not change much. With 30 kGy the conversion ratio significantly increases and reaches a maximum value. With further increases in dose, the conversion ratio quickly declines. With increasing gamma-ray dose, the CPC morphology becomes more porous/loose and apatite particles become larger in size. When exposed to a high dose (120 kGy) of gamma-radiation, TTCP structure is radiation-damaged, and gamma-ray-induced formation of apatite is confirmed by transmission electron microscopic/selected-area diffraction/lattice imaging analyses.

Bone Cements↗

Influence of initial component temperature on the apparent viscosity and handling characteristics of acrylic (PMMA) bone cement.

The flow and polymerization characteristics of poly(methylmethacrylate) (PMMA) bone cement can be changed by manipulating the temperature of the bone cement components or the environment that they are prepared in. To quantify the effects of the initial component temperature (T(ic)) of acrylic bone cement on the rheological and handling characteristics, ASTM F451-99a compliant methods and clinically relevant testing methods were utilized. A rheometer was designed and fabricated using the dimensions of a clinical, commercially available, cement gun and nozzle. The influence on the apparent viscosity and handling characteristics (setting time, working time, and peak exotherm temperature) for a high viscosity (HV) commercially-available acrylic bone cement, Palacos R, were determined. The values of T(ic) used were 23 degrees C (room), 6 degrees C (refrigerator), and -14 degrees C (freezer). Using the apparent viscosity of a medium viscosity (MV) bone cement as a benchmark (Simplex P at room temperature), it was found that by adjusting the T(ic) the HV cement was able to mimic the flow characteristics of the MV cement. Lowering the T(ic) lowered the apparent viscosity of the bone cement. The effects of T(ic) on the polymerization of bone cement were studied in dynamic and static conditions. The dynamic test recorded temperature and torque from stirring resistance. Setting times were also determined using the ASTM exotherm mold method. The setting times determined by the dynamic testing conditions were consistently shorter than those determined by the ASTM method. Lowering the T(ic) increased the working and setting times; however, it did not have a significant effect on the peak exotherm temperature.

Bone Cements↗