PubMed Health⌕ Search

PubMed · 10412559

Extracellular matrix: understanding the complexity.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Borojevic. 1999. Extracellular matrix: understanding the complexity.. https://doi.org/10.1590/s0100-879x1999000500001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Manipulation of selective cell adhesion and growth by surface charges of electrically polarized hydroxyapatite.

Adherence of cells to a surface, such as a biomaterial surface, can be significantly influenced by the surface charge on that material. The applicability of electrically charged hydroxyapatite ceramics to selective cell adhesion was examined, and we show that polarized hydroxyapatite has significant effects on cell growth and adhesion. The surface charge applied to polarized hydroxyapatite promotes (i) enhanced colony formation of osteoblast-like cells, (ii) activation of gap junctions, and (iii) specific orienting of neuroblastoma cells. These findings will be of great utility and have significance in applications of tissue engineering, for example, in potential treatments for osteoporosis.

Cell Adhesion↗

Shear-induced platelet activation and adhesion on human pulmonary artery endothelial cells seeded onto hydrophilic polymers.

We evaluated platelet activation and adhesion on two plasma polymerized surfaces, N-vinyl pyrrolidone (NVP) and gamma-butyro lactone (GBL), which have been shown previously to promote endothelial cell growth and adhesion as well as fibronectin-coated glass (1 microg/cm(2)) coverslips. Human pulmonary artery endothelial cells were seeded onto coverslips at a low density ( approximately 20,000 cells/cm(2)) and grown to confluence (3-5 days). The materials, both with and without ECs, were then exposed to a shear rate of 400 s(-1) in a closed loop recirculating flow system containing human platelet-rich plasma. Plasma samples were taken at 0, 5, 15, 30, and 60 min and analyzed for platelet and coagulation activation. The coverslips were examined for EC coverage and platelet adherence. EC retention over a 1-h period was approximately 75% for all three materials. All three materials without ECs were highly platelet activating having similar P-selectin expression, platelet factor 4 (PF4) release, mepacrine uptake, and microparticle production. Both microparticle production and platelet adhesion were significantly lower in EC-seeded materials. Dense granule and PF4 release were both slightly diminished in all three materials seeded with ECs. P-selectin expression was reduced slightly for GBL, but remained the same for the other two materials. The EC-seeded materials displayed favorable characteristics with respect to platelet activation and adhesion; however, they still demonstrated some thrombogenic tendencies due to EC loss and exposure of the underlying substrate. Therefore, both EC coverage and EC hemostatic function are important factors in determining the thromboresistance of an EC-seeded surface.

Cell Adhesion↗

Immobilized IL-8 triggers progressive activation of neutrophils rolling in vitro on P-selectin and intercellular adhesion molecule-1.

The chemokine IL-8 is found on the luminal side of vascular endothelial cells, where it is postulated to be immobilized during inflammation. In this study, we observed that immobilized IL-8 can stimulate neutrophils to firmly adhere to a substrate containing ICAM-1 in a static adhesion assay. Soluble IL-8 was then perfused over neutrophils rolling on P-selectin (P-sel) and ICAM-1, confirming that IL-8 in solution can quickly cause rolling neutrophils to arrest. To mimic a blood vessel wall with IL-8 expressed on the luminal surface of endothelial cells, IL-8 was immobilized along with P-sel and ICAM-1 at defined site densities to a surface. Neutrophils rolled an average of 200 microm on surfaces of P-sel, ICAM-1, and IL-8 before firmly adhering through ICAM-1-beta(2) integrin interactions at 2 dynes/cm(2) wall shear stress. Increasing the density of IL-8 from 60 to 350 sites/microm(2) on the surface decreased by 50% the average distance and time the neutrophils rolled before becoming firmly adherent. Temporal dynamics of ICAM-1-beta(2) integrin interactions of rolling neutrophils following IL-8 exposure suggest the existence of two classes of beta(2) integrin-ICAM-1 interactions, a low avidity interaction with a 65% increase in pause times as compared with P-sel-P-sel glycoprotein ligand-1 interactions, and a high avidity interaction with pause times 400% greater than the selectin interactions. Based on the proportionality between IL-8 site density and time to arrest, it appears that neutrophils may need to sample a critical number of IL-8 molecules presented by the vessel wall before forming a sufficient number of high avidity beta(2) integrin bonds for firm adhesion.

Cell Adhesion↗