PubMed Health⌕ Search

PubMed · 10415201

Second step: testing-outcome measurements.

Abstract

Despite worldwide enthusiasm for endoscopic surgery, this new technology is now on the top of McKinlay's "product life circle curve." Critical questions are being asked about its benefits and burdens, but the concepts applied and the methodologies used for technology assessment are in a similar position as endoscopic surgery and need a critical evaluation. (1) There are incorrect and outdated concepts for the scientific basis of surgery (surgical theory) including the basic sciences involved; biomedicine still dominates, but assessment of outcome after operations is no longer possible without clinical epidemiology and social psychology. (2) Based on an outdated scientific theory for surgery, an outdated concept of disease is still propagated. It is denoted as mechanical and is based solely on biomedicine. Human subjects are reduced to biologic machines, and outcomes measurement excludes most dimensions of functioning and well-being. To achieve a valid result for outcome measures, a hermeneutic approach must be combined with the mechanical approach. (3) Based on an outdated model of disease, the outcomes used in endoscopic surgery rely too much on traditional measures, such as mortality rate, complication rate, hospital stay, and especially an endless list of biochemical mediators. Their alterations during the perioperative period have not yet been shown to be related to clinical or hermeneutic outcomes. A new method of assessment for clinical trials in endoscopic surgery and for other surgical problems is outlined, such as for surgical infections and for surgical oncology. It includes an index of recovery and objective health status assessed by the doctor, a quality-of-life self-report by the patient, and the true endpoint concept as a critical weighting of both types of outcome by patients and doctors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Lorenz, H Troidl, J S Solomkin, C Nies, H Sitter, M Koller, W Krack, M F Roizen. 1999. Second step: testing-outcome measurements.. https://doi.org/10.1007/s002689900578

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Endoscopic endonasal transsphenoidal surgery: procedure, endoscopic equipment and instrumentation.

INTRODUCTION: In the last 10 years the endoscopic endonasal transsphenoidal approach has been proposed as a minimally invasive procedure for the treatment of pathologies of the sellar region. This procedure introduces various advantages compared with the transsphenoidal microsurgical approach such as a wider vision of the surgical field, less traumatism of the nasal structures, greater facility in the treatment of possible recurrences, and reduced complications. Nevertheless, as for any new procedure, there is an initial learning curve that is somewhat steep, due to the necessity of acquiring the specific endoscopic skills. It is equally essential to be supplied with dedicated endoscopic equipment and appropriate surgical instrumentation, in order to optimize the different stages of the operation. DISCUSSION: Therefore, after our extensive experience with over 250 patients treated by means of the endoscopic endonasal transsphenoidal approach for pathologies of the sellar region, we describe herein the characteristics of the proper endoscopic instrumentation, as well as a set of surgical instruments intentionally conceived to respond to the specific characteristics of this new procedure.

Endoscopy↗

Endoscopic third ventriculostomy in infants of less than 1 year of age: which factors influence the outcome?

OBJECTIVES: Endoscopic third ventriculostomy (ETV) is a successful method of treatment for obstructive hydrocephalus. In infants, however, it is reported to have a higher failure rate. On the basis of our own data and a meta-analysis of the literature, we try to define factors prognosticating potential failure in infants aged less than 1 year. METHODS: Data were collected retrospectively. Between October 1994 and October 2002, 20 ETVs were performed in 16 patients younger than 1 year. Ages ranged from 8 to 311 days (median 103). Etiology was aqueductal stenosis in all 16 patients (idiopathic in 7, posthemorrhagic in 3, postmeningitic in 3, and related to CNS or vascular malformation in 3). ETV failure was defined as subsequent need for shunt implantation. For non-shunted patients, follow up was 16-52 months (median 25). RESULTS: ETV was successful in 5 patients and eventually failed in 11. There was no mortality or permanent morbidity following ETV. In the successful cases, etiology was idiopathic aqueductal stenosis in 4 and postmeningitic aqueductal stenosis in 1; the median age was 206 days (range 82-311). In the 11 unsuccessful patients, it was idiopathic aqueductal stenosis in 3, posthemorrhagic in 3, postmeningitic in 2 and CNS/vascular malformation in 3 cases; median age was 94 days (range 8-299). Median time interval between (last) ETV and shunt was 38 days (range 2-70). The difference in median age between the success group and the failure group roughly corresponded to data gained from a meta-analysis of the literature. Four patients underwent a second ETV. In intraoperative ventriculoscopy, the stoma was closed or there were new membranes below the floor of the third ventricle and a second ETV was performed. But finally, all re-ETVs failed and the patients needed a shunt. CONCLUSION: Factors indicating potential failure of ETV were very young age and etiology other than idiopathic aqueductal stenosis. Probability of success seems to increase during the first 2 or 3 months of life. Ventriculoscopy with the option of a second ETV should be regularly performed after failure of ETV.

Endoscopy↗