PubMed Health⌕ Search

PubMed · 10431461

The human vector magnetogastrogram and magnetoenterogram.

Abstract

Electrical activity in the gastrointestinal system produces magnetic fields that may be measured with superconducting quantum interference device magnetometers. Although typical magnetometers have detection coils that measure a single component of the magnetic field, gastric and intestinal magnetic fields are vector quantities. We recorded gastric and intestinal magnetic fields from nine abdominal sections in nine normal human volunteers using a vector magnetometer that measures all three Cartesian components of the magnetic field vector. A vector projection technique was utilized to separate the magnetic field vectors corresponding to gastric and intestinal activity. The gastric magnetic field vector was oriented in a cephalad direction, consistent with previously observed data, and displayed oscillatory characteristics of gastric electrical activity (f = 3.03 +/- 0.18 cycles/min). Although the small bowel magnetic field vector showed no consistent orientation, the characteristic frequency gradient of the small bowel electrical activity was observed. Gastric and intestinal magnetic field vectors were oriented in different directions and were thus distinguished by the vector projection technique. The observed difference in direction of gastric and intestinal magnetic field vectors indicates that vector recordings dramatically increase the ability to separate physiological signal components from nonphysiological components and to distinguish between different physiological components.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L A Bradshaw, J K Ladipo, D J Staton, J P Wikswo, W O Richards. 1999. The human vector magnetogastrogram and magnetoenterogram.. https://doi.org/10.1109/10.775406

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Visual and colorimetric lithium ion sensing based on digital color analysis.

A new optical analytical method, "Digital Color Analysis (DCA)", is proposed based on a digital color analyzer instead of the conventional optical methodology, "Spectrophotometry". The digital color analyzer is a hand-held-size instrument for measuring "colors", and it can transform the color information into numerical values, color library data, etc., that can be treated as analytical information. DCA gives us a more informative analytical method than spectrophotometry by treating colors as digital information. In addition, DCA can also simulate the optimum color variations for optimization of the visual sensor with computer assistance. By utilizing colors as digital information, colorimetric analysis that has been used for only semiquantitative analysis can serve as an accurate determination method. On the basis of DCA, we developed a plasticized PVC film optode and a paper optode for Li+ determination in saliva. After the optimization of color variation and the detection range for the Li+ measurements, the optode membrane gives colorless gray in the Li+ therapeutic range (at 10(-3) M) in saliva. Consequently, whether or not the optimum therapeutic Li+ concentration is maintained can be easily evaluated with these optodes. Especially, the sensing paper optode can be easily handled within a short measurement time (approximately 80 s) which is suitable for home use. Using the digital color analyzer with QxQy coordinates, a linear relation calibration curve can be obtained over the range from 10(-5) to 10(-1) M Li+, in which the analyzer can detect a concentration difference of approximately 0.1 mM Li+. For the near future, an accurate and simple analysis is needed for a health check at home that does not require going to a hospital. The optode based on DCA has great potential for this analytical purpose.

Analog-Digital Conversion↗

[Clinical comparison of a digital with an analog hearing aid].

The benefit of innovative hearing aid technology can be evaluated in clinical trials. The present study describes the comparison of a new digital hearing aid with an analogue device serving as a reference. The tests were carried out with 15 experienced hearing aid wearers. To prevent the influence of different fitting algorithms such as prescriptive or loudness-based the digital devices were not renewed fitted but their level- and frequency-depending gain was adjusted to that of the reference. Different tests concerning loudness perception (category loudness scaling) speech discrimination in noise (the Göttingen sentence test) and self-assessment of the benefit by questionnaires were performed. All tests yielded slightly better results for the digital hearing aid. The speech audiometric evaluation showed somewhat better discrimination for the test-device. The questionnaires yielded a marked preference for the digital device. Because the study was not blinded influences due to the knowledge of the subjects of testing a new technology generally can occur. On the other hand, the question arises whether present audiometric tests sufficiently consider signal processing of modern hearing systems. Furthermore, one has to take into account that only a few of the features of digital technology such as noise-reduction and feedback-cancellation were considered in this study to allow for a sensible comparison. Because of the large number of possibilities offered by digital technology additional benefit by the hearing aid can be expected.

Analog-Digital Conversion↗

Lumped parameter estimation for the embryonic chick vascular system: a time-domain approach using MLAB.

We have evaluated several lumped parameter analog models for the early chick embryonic vascular system that may be used to infer loading characteristics of the developing heart. We measured dorsal aortic pressure and flow simultaneously with a servo-null pressure system and a pulsed Doppler velocimeter. Four different analog circuit models were chosen for comparisons. We formulated the time-domain differential equations specifying the relations between pressure and flow in the models, and then estimated the lumped parameters that produced the best fit. The MLAB mathematical modeling software was used for solving differential equations, and for minimizing the difference between model-predicted values and experimental data. The traditional three-element Windkessel model with an added inductance term was most often the best-fitting model. This is compatible with the previous study using a frequency-domain approach. The procedures developed for the current study are adaptable for the study of a variety of nonlinear models, and distributed parameter models for mammalian cardiovascular development with mechanically, pharmacologically, or genetically altered conditions.

Analog-Digital Conversion↗