PubMed Health⌕ Search

PubMed · 10432813

[Man with left coxalgia].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Casado Buendía, M C Galindo Soler, O Parrilla Ulloa, A Asiel Batian. 1999. [Man with left coxalgia].. https://pubmed.ncbi.nlm.nih.gov/10432813/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Rare complication of a heparin-induced thrombocytopenia type II].

HISTORY AND CLINICAL FINDINGS: A 63-year-old man was admitted to a surgery department with fracture of the acetabulum and luxation of the hip joint. Eight days after intracondylar nail-extension during subcutaneous heparin prophylaxis he developed a dramatic deterioration of his condition with severe abdominal pain and fever and was admitted to our hospital. INVESTIGATIONS: White cell count was 12,000/microliter, C-reactive protein 7.90 mg/dl. CT-scan, abdominal ultrasound, mesenteric angiography and exploratory laparotomy revealed no pathological findings. At day 13 abdominal ultrasound showed adrenal haemorrhages on the right. Together with a drop in platelet count below 50,000/microliter, adrenal haemorrhage caused by heparin-induced thrombocytopenia (type II; immunological [HIT II]) was suggested. THERAPY: After discontinuation of heparin and starting therapy with recombinant hirudin and hydrocortisone, a dramatic clinical recovery followed within 24 hours. One year after the initial diagnosis the patient is in a good condition. CONCLUSION: When abdominal pain, hypotension and fever occurs with a drop in platelet count during heparin therapy HIT II should be considered. An early diagnosis is essential for treatment of this life-threatening complication at an early stage.

Acetabulum↗

[Magnetic resonance arthrography of the hip joint in patients with suspected rupture of labrum acetabulare].

INTRODUCTION: MR arthrography by direct joint puncture and instillation of contrast medium is a minimally-invasive diagnostic technique in patients with suspected acetabular labral tear. The joint is distended, and the intraarticular structures are well separated. MATERIAL AND METHODS: 31 patients with chronic hip joint pain underwent MR arthrography by direct joint puncture and instillation of diluted gadolinium to evaluate the glenoid labrum. RESULTS: The glenoid labrum was seen in all patients. Labral tear was found in ten patients. Two of these underwent arthroscopy, and the tears were verified. We also found other causes of hip pain. One patient with villonodular synovitis at MR arthrography was verified at arthroscopy. INTERPRETATION: MR arthrography is a promising diagnostic technique for evaluating the acetabular labrum.

Acetabulum↗

Time- and depth-dependent changes in crosslinking and oxidation of shelf-aged polyethylene acetabular liners.

Since crosslinking and oxidation of ultrahigh-molecular-weight polyethylene (UHMWPE) have important roles in determining the wear resistance of UHMWPE total joint components, the time and depth dependence of crosslinking and oxidation of new shelf-aged (2-11 years), ready-to-implant acetabular liners were studied by using solvent extraction and Fourier transform infrared spectroscopy. The ultrastructure of these materials also was examined by using low-voltage scanning electron microscopy in an oil-free vacuum. Oxidation levels increased with time and with depth (p < 0.0001) from the surface of the older liners to a maximum value at about 1-2 mm below the surface, then decreased. They were minimal at the midsection of the liners. The crosslinking of these liners decreased with time and depth (p < 0.0001) and was inversely proportional to the level of oxidation. High and depth-dependent oxidation levels were observed in all older liners made from GUR 415 and 412 resins but were distinctly absent from a comparably aged (i.e., 9 years) liner made from 1900 CM-resin. Some liners showed varying degrees of inhomogeneous and discontinuous morphologic ultrastructure in addition to varying amounts of porosity while others had a more homogeneous ultrastructure. Oxidation and crosslinking of polyethylene are time- and depth-dependent processes that are mutually competitive. We suggest that resin choice and perhaps consolidation-related variables lead to differences in polyethylene's ultrastructure. These ultrastructural differences in polyethylene's inhomogeneities, that is, the type (interconnected or closed-cell) or extent may affect the oxidation resistance of polyethylene. While oxygen diffusion to free radicals in polyethylene already is known to explain some of these time- and depth-dependent effects, perhaps such ultrastructural variations also may facilitate or retard oxygen diffusion in this material. Resin-based ultrastructural variability partially may explain the variability in the clinical performance of polyethylene total joint implant components. Thus resin choice or processing modifications related to polyethylene's ultrastructure may increase its oxidation resistance and ultimately improve the clinical wear performance of polyethylene total joint orthopedic implants.

Acetabulum↗