Characterization of bone quality using computer-extracted radiographic features.

Abstract

Both bone mineral density (BMD) and trabecular structure are important determinates of bone mechanical properties. However, neither BMD or trabecular structural features can completely explain the variations in bone mechanical properties. In this study, we combine BMD and bone structural features to characterize bone mechanical behavior. Radiographs were obtained from 34 femoral neck specimens excised during total hip arthroplasties. Each neck radiograph was digitized and a region of interest (ROI) was selected from the medial side of the femoral neck. Textural features, the global Minkoswski dimension and trabecular orientation, were extracted from each ROI image using Minkowski dimension analysis. The BMD of each specimen was measured using dual-energy x-ray absorptiometry (DXA) and subsequently normalized by bone size as measured from a standard pelvis radiograph. Mechanical testing was performed on the trabecular bone cubes machined from each femoral neck to yield bone mechanical properties. Multiple regression was performed to select the best features to predict bone mechanical properties. The results suggest that, using multiple predictors including normalized BMD structural features, and patient age, the coefficients of determination (R2) improved over the use of BMD alone. For bone strength, the R2 was improved from 0.24 using conventional BMD to 0.48 using a four-predictor model. Similar results were obtained in the prediction of Young's modulus, i.e., the R2 was improved from 0.25 to 0.55 in going from the model using conventional BMD to a four-predictor model. This study demonstrates the contributions of normalized BMD, structural features, and age to bone mechanical properties, and suggests a potential method for the noninvasive evaluation of bone mechanical properties.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Jiang, M L Giger, M R Chinander, J M Martell, S Kwak, M J Favus. 1999. Characterization of bone quality using computer-extracted radiographic features.. https://doi.org/10.1118/1.598604

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗