PubMed Health⌕ Search

PubMed · 10441892

Key developments in knee surgery.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Isdale, P Helliwell. 1998. Key developments in knee surgery.. https://pubmed.ncbi.nlm.nih.gov/10441892/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Chromosomal changes in a dedifferentiated chondrosarcoma: a case report and review of the literature.

The chromosome abnormalities observed in a dedifferentiated chondrosarcoma are reported. A new molecular cytogenetic technique, spectral karyotyping, was used to identify and confirm structural rearrangements in this case. A review of the literature revealed that nine cases have been reported, in eight of which a complete description of the cytogenetic abnormalities was described. Structural aberrations were most frequently reported in chromosomes 1 and 9, and chromosomes 7 and 19 were most frequently observed to be involved in numerical aberrations (trisomy and tetrasomy). In chondrosarcomas, structural aberrations in chromosomes 1 and 9 and trisomy or tetrasomy of chromosome 7 are among the more frequently observed aberrations.

Arthroplasty, Replacement, Knee↗

Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics.

The effect of manufacturing process on the wear and mechanical performance of a total knee replacement (TKR) design was investigated with the use of a force-controlled knee joint simulator. Ultra-high molecular weight polyethylene (UHMWPE) tibial inserts processed by direct compression molding from 1900H resin were compared to UHMWPE tibial inserts machined from a compression-molded sheet of GUR 1050. Both sets of components had the same posterior-cruciate-retaining geometry, and were identically aligned with cobalt-chromium-molybdenum alloy femoral components. Wear tests were conducted at a frequency of 1 Hz for 4 million cycles with the use of a standard walking cycle pattern. Implant kinematics, including anterior-posterior (AP) displacement and internal-external (IE) rotation in response to applied loads were monitored. Gravimetric wear, surface roughness, and surface morphology were used to characterize the wear process of the UHMWPE inserts. Results showed that the molded UHMWPE inserts exhibited less gravimetric wear over time than the machined inserts of the same design. Both the machined and molded components exhibited scratching, pitting, and burnishing over their wear areas. The AP displacement distance per cycle of the molded tibial inserts decreased over the course of testing, resulting in a shorter total testing displacement for this group compared to machined tibial inserts. Although AP displacement distance per cycle for machined tibial inserts did not change significantly over the course of testing, their position relative to the femoral components shifted posteriorly over time, resulting in an elongated wear track.

Arthroplasty, Replacement, Knee↗

The patella in total knee replacement: technical aspects on the femoral side.

The influence of femoral component positioning on patellar tracking is critical. The various possibilities of modifying the position of the femoral component relative to the distal femoral epiphysis are analyzed, and the ideal positioning in the medio-lateral, antero-posterior, and proximal-distal directions is described. Special emphasis is placed on the rotational positioning of the femoral component.

Arthroplasty, Replacement, Knee↗