A comparative study of colloidal particles as imaging standards for microscopy.

Abstract

Colloidal particles have long been used as imaging standards for electron microscopy and, more recently, for scanning probe microscopy. We have analysed gold, polystyrene and silica colloidal particles by both transmission electron microscopy and atomic/scanning force microscopy in an attempt to determine if any can be truly used as 'standards' of shape and/or size. From the transmission electron micrographs, we have obtained precise information of the particle circumference and mean diameter. By comparing the ratio of these to the value for pi, we obtained a measure of the sphericity of the particles. We have also shadowed the particles with metal at a known angle and have analysed the shadow length to determine the particles' heights and shapes. The height information obtained from the shadow length data collected from the transmission electron micrographs was then compared with that obtained by atomic/scanning force microscopy. Our results show that cleaned (washed) silica or polystyrene particles closely approach true spheres. In the case of gold particles, height data obtained from shadow lengths analysed in transmission electron micrographs show good agreement with that obtained from the atomic/scanning force microscopy images even without washing. However, the gold particles often deviate from sphericity. Based upon both the shape and the physical properties of the colloidal particles, silica would be the best choice as a standard. We also have noticed that metal shadowing of colloidal particle samples used for atomic/scanning force microscopy offers an advantage which we call a 'nanoscale metric' visible in the image directly at each particle site. This information can be important if one wishes to use samples prepared from colloidal particles simply and reliably to determine the probe shape for scanning probe microscopy from image deconvolution/restoration methods or as a calibration sample.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Derose, J Revel. 1999. A comparative study of colloidal particles as imaging standards for microscopy.. https://doi.org/10.1046/j.1365-2818.1999.00490.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗