PubMed Health⌕ Search

PubMed · 10452708

Biofeedback systems architecture.

Abstract

The capability for a dialysis machine to use a measurement of the patient's status to automatically tune the dialysis session on-line is commonly addressed by physicians and bioengineers working in the hemodialysis field as "biofeedback." This paper presents the basics of mathematical modeling and control theory normally used in bioengineering, together with some advanced techniques, such as adaptive and multi-input/multi-output control systems. The architectural requirements for implementing biofeedback techniques in renal replacement therapy are then discussed, with due attention paid to the safety aspects, which play a central role in machines hosting such new techniques as well as their therapeutic mission. Finally, the blood volume tracking system, which is aimed at performing the intradialytic water removal, while maintaining a balance inside the body fluids compartments and thus preserving cardiovascular stability, is used as a paradigmatic example of such a class of advanced techniques. The significant results shown by the blood-volume-controlled treatments during a multicenter study focused on its clinical application (30% reduction of intradialysis collapses, 13% reduction of interdialysis symptoms) indicate the technical feasibility and the remarkable benefits of such systems, which get closer to a structurally complete artificial kidney.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Paolini, A Bosetto. 1999. Biofeedback systems architecture.. https://doi.org/10.1016/s1073-4449(99)70021-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Array-to-array transfer of an artificial nose classifier.

This paper describes the use of a microsphere sensor technology that allows simple fabrication of vapor sensor arrays with reproducible response patterns. Microsphere sensor fabrication protocols are uncomplicated and yield billions of highly reproducible sensors. Microsphere sensor arrays combined with a generalized Whitney-Mann-Wilcoxen (GWMW) classifier were used to discriminate between the presence and absence of nitroaromatic compounds in high background vapor mixtures. The classifier was trained on one sensor array and then used to obtain 98.2 and 93.7% correct classification rates with data collected using two subsequent arrays made up to six months after the initial training was performed. These results represent an advance in the ability to transfer training data between multiple sensor arrays with a fluorescence-based artificial nose.

Artificial Organs↗

The replacements.

Explore the source record for details and available documents.

Artificial Organs↗

[Dermatography. An effective method for pacemaker marking after spinal cord injuries and implantation of a Brindley stimulator for neurogenic bladder].

In our department, two spinal cord lesion patients suffering from neurogenic bladder dysfunction were selected for the implantation of a Brindley stimulator, as they could not be managed by conservative treatment. Accurate positioning of the external transmitter block over the subcutaneous receiver block, which is essential for the Brindley stimulator to function correctly, posed problems for the relatives who had to apply the external transmitter. In order to facilitate positioning, dermatography was used to mark the exact spot where the external transmitter should be placed. A 3-year follow-up showed that this marking solved the problem completely and that recurrent urinary tract infections stopped.

Artificial Organs↗