Simple phantom for gamma camera spatial resolution objective measurement.

Abstract

This paper presents a simply designed line source phantom for gamma camera spatial resolution measurement. It can be useful for the nuclear medicine departments where sophisticated spatial resolution measuring tools are not available; it can be used both in routine and in reference tests of gamma camera spatial resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Kostourkov. 1999. Simple phantom for gamma camera spatial resolution objective measurement.. https://pubmed.ncbi.nlm.nih.gov/10462921/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Accuracy of the quantification of organ activity from planar gamma camera images.

The accuracy in determination of organ activity of (99m)Tc was investigated, with activity estimated from gamma camera images of phantoms, using the conjugate view method. The accuracy depends on several parameters such as the choice of background correction method, the accuracy in determination of the effective attenuation coefficient and the thickness of the body and organs and on the determination of the gamma camera sensitivity. The background correction method has a major influence on the quantification of the activity. Methods which take the volume of the source organ into consideration are recommended. The discrepancy in the determined organ activity varied between an underestimation of 26% and an overestimation of 16% in the MIRD phantom, depending on which organ was studied and on the correction method used. To correct for absorption and scattering, an effective attenuation coefficient was used. A theoretical analysis showed that a change in the effective attenuation coefficient of 0.01 cm(-1) resulted in a 15% change in the calculated activity. Also the thickness of the body and the organ of interest influences the calculated activity. A 2 cm deviation in the body thickness causes a deviation of approximately 10% in the calculated activity. The quantification is improved if the attenuation coefficient is determined by transmission measurements.

Gamma Cameras↗

[Performance evaluation of dual-head coincidence gamma camera for positron imaging].

AIM AND METHODS: We assessed the performance evaluation of a dual-head coincidence gamma camera (Millennium VG, General Electric, Milwaukee, USA) as a positron emission tomography (PET) scanner based on the measurement indicator for performance evaluation of PET device. RESULTS: The axial spatial resolution was 4.98 mm FWHM at the center of the field of view. The true high count-rate characteristic curve was relatively straight within the range 0-0.2 microCi/ml. The relative recovery coefficient was 0.1 with a diameter of 10 mm and 0.39 with a diameter of 20 mm. CONCLUSION: In this study, we had to make a some change in the protocols described in the measurement indicator for performance evaluation of PET devices.

Gamma Cameras↗