PubMed Health⌕ Search

PubMed · 10464944

Dynamic frequency change influences loudness perception: a central, analytic process.

Abstract

Three experiments showed that dynamic frequency change influenced loudness. Listeners heard tones that had concurrent frequency and intensity change and tracked loudness while ignoring pitch. Dynamic frequency change significantly influenced loudness. A control experiment showed that the effect depended on dynamic change and was opposite that predicted by static equal loudness contours. In a 3rd experiment, listeners heard white noise intensity change in one ear and harmonic frequency change in the other and tracked the loudness of the noise while ignoring the harmonic tone. Findings suggest that the dynamic interaction of pitch and loudness occurs centrally in the auditory system; is an analytic process; has evolved to take advantage of naturally occurring covariation of frequency and intensity; and reflects a shortcoming of traditional static models of loudness perception in a dynamic natural setting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J G Neuhoff, M K McBeath, W C Wanzie. 1999. Dynamic frequency change influences loudness perception: a central, analytic process.. https://doi.org/10.1037/%2F0096-1523.25.4.1050

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sensitivity of the acoustic waveguide biosensor to protein binding as a function of the waveguide properties.

The aim of this work is to study the effect of operating frequency, piezoelectric substrate and waveguide layer thickness on the sensitivity of the acoustic waveguide sensor during the specific binding of an antibody by a protein. Shear horizontal (SH) wave devices consisting of (a) a LiTaO3 substrate operating at 104 MHz, (b) a quartz substrate operating at 108 MHz and (c) a quartz substrate operating at 155 MHz were coated with a photoresist polymer layer in order to produce acoustic waveguide devices supporting a Love wave. The effect of the thickness of the polymer layer on the Love wave was assessed by measuring the amplitude and phase of the wave before and after coating. The sensitivity of the above three biosensors was compared during the detection of the specific binding of different concentrations of Immunoglobulin G in the range of 0.7-667 nM to a protein A modified surface. Results indicate that the thickness of the polymer guiding layer is critical for obtaining the maximum sensitivity for a given geometry but a trade-off has to be made between the theoretically determined optimum thickness for waveguiding and the device insertion loss. It was also found that increasing the frequency of operation results in a further increase in the device sensitivity to protein detection.

Acoustics↗

Study of the diffusion of some emulsions in the human skin by pulsed photoacoustic spectroscopy.

We previously used pulsed photoacoustic spectroscopy (PPAS) to quantify sunscreen diffusion into human skin, and suggested a methodology to evaluate the time and the depth diffusion profile. These results were obtained by the analysis of the photoacoustic maximum response signal Pmax decrease, the time delay tmax and the Fourier transform representation of the photoacoustic signal. In this study we present the results obtained for diffusion of four typical emulsions used in sunscreen compositions that show, for the first time, a particular behaviour for one of these emulsions due to a chemical reaction inside the skin during the diffusion process. This result provides a particularly interesting technique through the PPAS, to evaluate in situ the eventual chemical reactions that can occur during drug diffusion into human skin.

Acoustics↗