PubMed Health⌕ Search

PubMed · 10468381

Screening for adverse events.

Abstract

Adverse events (AEs) in medical patients are common, costly, and often preventable. Development of quality improvement programs to decrease the number and impact of AEs demands effective methods for screening for AEs on a routine basis. Here we describe the impact, types, and potential causes of AEs and review various techniques for identifying AEs. We evaluate the use of generic screening criteria in detail and describe a recent study of the sensitivity and specificity of individual generic screening criteria and combinations of these criteria. In general, the most sensitive screens were the least specific and no small sub-set of screens identified a large percentage of adverse events. Combinations of screens that were limited to administrative data were the least expensive, but none were particularly sensitive, although in practice they might be effective since routine screening is currently rarely done. As computer systems increase in sophistication sensitivity will improve. We also discuss recent studies that suggest that programs that screen for and identify AEs can be useful in reducing AE rates. While tools for identifying AEs have strengths and weaknesses, they can play an important role in organizations' quality improvement portfolios.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A S Karson, D W Bates. 1999. Screening for adverse events.. https://doi.org/10.1046/j.1365-2753.1999.00158.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Interrater agreement with a standard scheme for classifying medication errors.

PURPOSE: The interrater agreement for and reliability of the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP) index for categorizing medication errors were determined. METHODS: A letter was sent by the U.S. Pharmacopeia to all 550 contacts in the MEDMARX system user database. Participants were asked to categorize 27 medication scenarios using the NCC MERP index and were randomly assigned to one of three tools (the index alone, a paper-based algorithm, or a computer-based algorithm) to assist in categorization. Because the NCC MERP index accounts for harm and cost, and because categories could be interpreted as substantially similar, study results were analyzed after the nine error categories were collapsed to six. The interrater agreement was measured using Cohen's kappa value. RESULTS: Of 119 positive responses, 101 completed surveys were returned for a response rate of 85%. There were no significant differences in baseline demographics among the three groups. The overall interrater agreement for the participants, regardless of group assignment, was substantial at 0.61 (95% confidence interval [CI], 0.41-0.81). There was no difference among the kappa values of the three study groups and the tools used to aid in medication error classification. When the index was condensed from nine categories to six, the interrater agreement increased with a kappa value of 0.74 (95% CI, 0.56-0.90). CONCLUSION: Overall interrater agreement for the NCC MERP index for categorizing medication errors was substantial. The tool provided to assist with categorization did not influence overall categorization. Further refining of the scale could improve the usefulness and validity of medication error categorization.

Adverse Drug Reaction Reporting Systems↗

Post Launch Monitoring of food products: what can be learned from pharmacovigilance.

Post Launch Monitoring (PLM) is one of the new approaches that are used in assessing the safety of novel foods or ingredients. It shares a close resemblance with procedures applied in the field of medicines, where Post Marketing Surveillance (PMS) has been carried out since the beginning of the 1960s. For this reason, Unilever and the Netherlands Pharmacovigilance Centre Lareb, maintaining the national reporting scheme in the Netherlands for adverse drug reactions, have been working together to optimize the Unilever's Post Launch Monitoring service. As a result of this cooperation a practical model for conducting PLM for food products has been developed. This model is also applicable for consumer products in general. The system allows for coding and assessing reports and the early detection of 'signals' of unintended health reactions. The methodological issues surrounding reporting of possible health reactions and practical issues surrounding coding and assessment of the reports that were encountered in the first period of this partnership are discussed. In addition, similarities and differences concerning PMS and PLM are described.

Adverse Drug Reaction Reporting Systems↗