PubMed Health⌕ Search

PubMed · 10488402

Height, body size and longevity.

Abstract

Life expectancy, mortality and longevity data related to height and body size for various US and world population samples are reviewed. Research on energy restriction, smaller body size and longevity is also examined. Information sources include various medical and scientific journals, books and personal communications with researchers. Additional information is presented based on research involving eight populations of the world noted for their health, vigor and longevity. This information includes the findings of one of the authors who led research teams to study these populations. While conflicting findings exist on the cardiovascular death rates for shorter people, many examples of short populations with very little heart disease are described. Most cancer studies indicate that shorter people have significantly lower mortality risk. Considerable data suggest that shorter people generally have greater longevity than taller people, and extensive animal research supports human longevity findings. Tall populations with low mortality rates are also described. Shorter stature and smaller body weight appear to promote better health and longevity in the absence of malnutrition and infectious diseases. Several theoretical reasons for this greater longevity potential are covered. Also discussed, is the role of socioeconomic status, diet, relative weight, environment and other factors in increasing or decreasing the longevity of individuals, regardless of their heights and weights.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T T Samaras, H Elrick. 1999. Height, body size and longevity.. https://pubmed.ncbi.nlm.nih.gov/10488402/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology.

Patient and staff dose values in an interventional cardiology laboratory for different operational modes and several patient thicknesses (from 16 to 28 cm, simulated using polymethylmethacrylate) are presented. When increasing patient thicknesses and depending on fluoroscopy and cine modes, occupational doses can increase >30 times the baseline level. Scatter dose rates at the cardiologist's position with no radiation protective tools ranged from 1 to 14 mSv h(-1) for fluoroscopy, and from 10 to 47 mSv h(-1) during cine acquisition. Patient entrance surface air kerma rates increased by nearly 3 and staff dose rates by up to 2.6 when fluoroscopy was moved from the low to the high mode, for a typical 20 cm thickness. The respective increase factors were 6 and 4.2 when patient thickness rose from 16 to 28 cm, and by 10 and 8.3, when comparing cine acquisition with the low fluoroscopy mode. The knowledge of typical dose rates for each X-ray system in use in catheterisation laboratories is essential in order to optimise protection of patients and staff.

Body Constitution↗

Simulator-assisted setting of scan protocols for X-ray CT: development and clinical usefulness of the Scan Plan Simulator.

To assist in the selection of complicated computed tomography (CT) scan protocols and to obtain stable image SD values, prototype "Scan Plan Simulator" software with the following functions was developed and evaluated. 1) The image SD value that will be obtained in actual scanning is estimated by entering the patient's body size and scan protocol, after which a simulated image is displayed so that the estimated image SD value can be checked. The exposure dose can also be estimated in the Scan Plan Simulator. 2) The appropriate tube current is automatically set by entering the required image SD value. We evaluated the accuracy of the Scan Plan Simulator by comparing the simulation results with the image SD values and exposure dose obtained in actual scanning and assessed the usefulness of this method using Monte Carlo simulation based on body thickness data obtained in clinical examinations. The results showed that the Scan Plan Simulator not only stabilizes image SD by minimizing the effects of body size but also permits the exposure dose to be reduced by optimizing tube current.

Body Constitution↗