PubMed Health⌕ Search

PubMed · 10498523

Shape-based grey-level image interpolation.

Abstract

The three-dimensional (3D) object data obtained from a CT scanner usually have unequal sampling frequencies in the x-, y- and z-directions. Generally, the 3D data are first interpolated between slices to obtain isotropic resolution, reconstructed, then operated on using object extraction and display algorithms. The traditional grey-level interpolation introduces a layer of intermediate substance and is not suitable for objects that are very different from the opposite background. The shape-based interpolation method transfers a pixel location to a parameter related to the object shape and the interpolation is performed on that parameter. This process is able to achieve a better interpolation but its application is limited to binary images only. In this paper, we present an improved shape-based interpolation method for grey-level images. The new method uses a polygon to approximate the object shape and performs the interpolation using polygon vertices as references. The binary images representing the shape of the object were first generated via image segmentation on the source images. The target object binary image was then created using regular shape-based interpolation. The polygon enclosing the object for each slice can be generated from the shape of that slice. We determined the relative location in the source slices of each pixel inside the target polygon using the vertices of a polygon as the reference. The target slice grey-level was interpolated from the corresponding source image pixels. The image quality of this interpolation method is better and the mean squared difference is smaller than with traditional grey-level interpolation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K S Chuang, C Y Chen, L J Yuan, C K Yeh. 1999. Shape-based grey-level image interpolation.. https://doi.org/10.1088/0031-9155%2F44%2F6%2F309. https://pubmed.health/record/pubmed%3A10498523/shape-based-grey-level-image-interpolation

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

[Molecular imaging with new PET tracers].

In the recent years, positron emission tomography (PET) has gained more and more importance, especially in oncology for primary staging, as well as for response evaluation. The glucose analogon (18)F-FDG is the most widely used tracer up to now. In this paper, we review the applications of newly developed, more specific PET tracers. These tracers allow for imaging of a variety of biological processes, such as hypoxia and proliferation. The expression of different receptors can be visualized, like the somatostatin receptor 2 and the integrin alphavbeta3. Moreover, gene expression can be imaged as well. While most of these approaches are currently in the first phases of clinical evaluation, imaging of hypoxia and proliferation might be integrated into the daily routine in the near future.

Image Enhancement↗