PubMed Health⌕ Search

PubMed · 10515402

Tolerance to beta-agonists during acute bronchoconstriction.

Abstract

Previous reports suggest that regular use of beta-agonists does not lead to tolerance to their bronchodilator effects. However, most studies have been conducted in stable asthma. This study investigates whether bronchodilator tolerance can be demonstrated during acute bronchoconstriction. Thirty-four asthmatic subjects were treated with 6 weeks inhaled terbutaline (1 mg q.i.d.), budesonide (400 microg, b.i.d.), both drugs or placebo in a randomized, double-blind, cross-over study. After each treatment methacholine was administered to induce a 20% fall in the forced expiratory volume in one second (FEV1). The response to inhaled salbutamol 100, 100, 200 microg at 5 min intervals) was then measured. Dose-response curves were compared using an analysis of covariance. Pre-methacholine FEV1, the highest pre-methacholine FEV1, the fall in FEV1 induced by methacholine and the logarithm of the provocative dose of methacholine required to induce the 20% fall in FEV1 (PD20) were used as covariates. There was a significantly reduced response to salbutamol after 6 weeks terbutaline treatment: the mean (95% confidence intervals (CI)) area under the dose-response curve was reduced by 36% (24, 47) compared to placebo (p<0.0001). The reduction in bronchodilator response was not affected by concomitant treatment with budesonide. Significant tolerance to the bronchodilator effect of inhaled beta-agonists may be demonstrated when tested during acute bronchoconstriction. Continuous treatment with inhaled beta-agonists may lead to a reduced response to emergency beta-agonist treatment during asthma exacerbations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Hancox, R E Aldridge, J O Cowan, E M Flannery, G P Herbison, C R McLachlan, G I Town, D R Taylor. 1999. Tolerance to beta-agonists during acute bronchoconstriction.. https://doi.org/10.1034/j.1399-3003.1999.14b08.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗