PubMed Health⌕ Search

PubMed · 10526786

Recent developments in microcolumn liquid chromatography.

Abstract

An overview of the most recent developments in microcolumn liquid chromatography (LC) is presented. A short theoretical discussion on chromatographic dilution and extracolumn bandbroadening is given and also the recent progress and advances in column technology and instrumentation are reviewed. However, the emphasis of this review is on miniaturized sample clean-up, sample introduction techniques and on both established and more recent detection techniques for microcolumn LC. The hyphenation of miniaturized LC columns with other techniques, specifically on multidimensional chromatography and the coupling of microcolumn LC to mass spectrometry is discussed in detail. Both the on-line and automated off-line interfacing to other separation and detection techniques will also be addressed. Finally, a number of typical microcolumn LC applications are presented in order to demonstrate the potential of microcolumn LC methods in a variety of scientific areas.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J P Vissers. 1999-09-24. Recent developments in microcolumn liquid chromatography.. https://doi.org/10.1016/s0021-9673(99)00692-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods to quantify alpha-tocopherol and alpha-tocopherolquinone levels in human plasma.

Two mass spectrometric methods were established for the quantitative analyses of alpha-tocopherol (TH) and its oxidation product alpha-tocopherolquinone (TQ) in human plasma. Both methods make use of isotopically labeled internal standards of different levels of deuteration (d3-TH and d6-TQ). Plasma (100 microl) was saponified in the presence of a mixture of antioxidants, and then TH and TQ were extracted with hexane. With the GC-MS method, the analytes were first converted into O-trimethylsilyl derivatives before analysis in the selective ion monitoring mode. The derivatization procedure led to the quantitative conversion of TQ into the O-trimethylsilyl derivative of tocopherolhydroquinone, giving rise to a more stable molecule with less fragmentation than for TQ. The increased stability of the molecule resulted in an enhanced contribution of the base peak to the total observed ions and therefore an increased sensitivity of the base peak for quantification. With the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, TH and TQ were detected by multiple reaction monitoring after positive electrospray ionization. The GC-MS and LC-MS/MS methods showed nearly the same accuracy (>95%) and the same within-day precisions, with less than 5 and 10% for TH and TQ, respectively. The between-day precision and the limit of quantification for TQ in plasma were better by LC-MS/MS (4%; 3 nM) than by GC-MS (21%; 10 nM). Analysis and method validation were carried out with plasma samples obtained from a male volunteer pre- and postexercise. Both techniques showed that the ratio of TQ/TH was elevated by 35% immediately after exercise and had returned to basal levels when measured 24 h later.

Chromatography, Liquid↗

Simultaneous determination of a novel M3 muscarinic receptor antagonist and its active 5-OH metabolite in human plasma using liquid chromatography/tandem mass spectrometry.

A sensitive, specific, and robust liquid chromatography (LC)/mass spectrometry (MS)/MS method has been developed and validated for a novel M(3) muscarinic receptor antagonist (I) and its active 5-OH metabolite (II) in human plasma. The assay involves a two-step liquid-liquid extraction of the compounds from human plasma, high performance liquid chromatography (HPLC) separation, and MS/MS for the detection of the analytes. The method provides a linear response from a quantitation limit of 0.05-20 ng/ml for I and 0.1-20 ng/ml for II using 1 ml of plasma. The mean absolute recovery was 85.4% for I and 80.8% for II, respectively. The intra-assay accuracy of I and II averaged from 95.0 to 105.3% with coefficient of variation (CV) values <or=6.5% over the standard curve range. The stability study showed that I and II are stable in the plasma matrix over a period of 11 months at -70 degrees C. The accuracy, ruggedness, and reproducibility of this method were demonstrated by analyzing over 5000 plasma samples in clinical pharmacokinetics studies over a 6-month period.

Chromatography, Liquid↗

Using a modified ferrous oxidation-xylenol orange (FOX) assay for detection of lipid hydroperoxides in plant tissue.

The ferrous oxidation-xylenol orange (FOX) assay was adapted for quantifying lipid hydroperoxides (LOOHs) in plant extracts. Excised pieces of several fruit and vegetable species were exposed to 83 kJ m(-2) day(-1) of biologically effective ultraviolet B irradiance (UV-B(BE)) for 10-12 days to induce cellular oxidation. The LOOH and thiobarbituric acid reactive substance (TBARS) concentrations of these plant tissues were assessed with the FOX and iodometric assays for the former and a modified TBARS assay for the latter. There was generally good agreement between the FOX and iodometric methods both prior to and following the UV exposure. However, the iodometric assay appeared to have some difficulty in consistently quantifying lower LOOH levels (<11 microM), whereas the FOX assay measured LOOH concentrations as low as 5 microM. All tissues exhibited UV-induced increases in TBARS, indicating a marked degree of cellular oxidation in the exposed tissue segments. Compared with the iodometric assay, the FOX method consistently generated less variable LOOH values. The presence of authentic linoleic acid-OOHs in spiked avocado and spinach samples (11 microM) was identified with liquid chromatography-mass spectrometry techniques, which validated corresponding FOX assay results. The FOX method is inexpensive, is not sensitive to ambient O2 or light levels, and can rapidly generate LOOH measurements. The physiological value of the FOX assay resides in its ability to measure initial rather than more advanced fatty acid oxidation; hence, early membrane-associated stress events in plant tissue can be detected.

Chromatography, Liquid↗