PubMed Health⌕ Search

PubMed · 10528979

A dissolution test for a pressure-controlled colon delivery capsule: rotating beads method.

Abstract

The rotating beads method is a new in-vitro dissolution test proposed for drugs formulated as pressure-controlled colon delivery capsules (PCDCs). The apparatus consisted of a glass vessel (500 mL) containing 4-mm (i.d.) glass beads (5000, 10000 or 15000) and dissolution medium (0-067 M phosphate buffer, pH 7; 25, 50 or 100 mL) containing polyvinyl alcohol (PVA; 5, 10 or 20 w/v%) to simulate the viscosity of the colon. The vessel was rotated at 5, 10 or 25 rev min(-1) and the temperature was maintained at 37 degrees C. Fluorescein was used as a model drug to explore the optimized conditions under which differences in the drug dissolution rate are detected between colon delivery systems. Fluorescein was formulated in four types of colon delivery systems. One was a tablet coated with an enteric polymer, Eudragit S-100, and the other three were PCDCs prepared with different thicknesses of ethylcellulose coating membrane (type I, II, III). The dissolution behaviour of fluorescein from the PCDC formulation was significantly different from that of the Eudragit S-100-coated tablets, when the dissolution conditions were as follows: rotation speed, 10 rev min(-1); bead number, 10000; dissolution medium, 50mL with 10% PVA. This dissolution method was applied to acetaminophen sustained-release tablets and two other drugs having low solubility in the colon, tegafur and 5-aminosalicylic acid. Similarly, significant differences in the dissolution rates of drugs from the PCDC formulation and the enteric tablet were detected. There was good correlation between the in-vitro dissolution rates and in-vivo absorption rates using T50 (the time for half of the amount of drug to be released from the preparation) and Cmax/Tmax (enteric tablet) or Cmax/(Tmax-Ti) (PCDC), where Ti is the first appearance time in the systemic circulation. The rotating beads method is a valuable technique for evaluating the dissolution rate of drugs formulated in PCDC.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Yoshikawa, Z Hu, G Kimura, M Murakami, H Yoshikawa, K Takada. 1999. A dissolution test for a pressure-controlled colon delivery capsule: rotating beads method.. https://doi.org/10.1211/0022357991773447

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recognition, perceptions and treatment practices for severe malaria in rural Tanzania: implications for accessing rectal artesunate as a pre-referral.

OBJECTIVES: Preparatory to a community trial investigating how best to deliver rectal artesunate as pre-referral treatment for severe malaria; local understanding, perceptions of signs/symptoms of severe malaria and treatment-seeking patterns for and barriers to seeking biomedical treatment were investigated. METHODOLOGY/PRINCIPAL FINDINGS: 19 key informant interviews, 12 in-depth interviews and 14 focus group discussions targeting care-givers, opinion leaders, and formal and informal health care providers were conducted. Monthly fever episodes and danger signs or symptoms associated with severe malaria among under-fives were recorded. Respondents recognized convulsions, altered consciousness and coma, and were aware of their risks if not treated. But, these symptoms were perceived to be caused by supernatural forces, and traditional healers were identified as primary care providers. With some delay, mothers eventually visited a health facility when convulsions were part of the illness, despite pressures against this. Although vomiting and failure to eat/suck/drink were associated with malaria, they were not considered as indicators of danger signs unless combined with another more severe symptom. Study communities were familiar with rectal application of medicines. CONCLUSIONS/SIGNIFICANCE: Communities' recognition and awareness of major symptoms of severe malaria could encourage action, but perceptions of their causes and poor discrimination of other danger signs - vomiting and failure to feed - might impede early treatment. An effective health education targeting parents/guardians, decision-makers/advisors, and formal and informal care providers might be a prerequisite for successful introduction of rectal artemisinins as an emergency treatment. Role of traditional healers in delivering such medication to the community should be explored.

Administration, Rectal↗

Application of 10 percent formalin for the treatment of radiation-induced hemorrhagic proctitis.

PURPOSE: Rectal instillation of 4 percent formalin solution has been described as a successful treatment for hemorrhagic radiation proctitis recalcitrant to medical treatment. We present our experience with a new method of treatment involving the topical application of 10 percent buffered formalin, which is well tolerated and suitable for office use. METHODS: Patients with marked or refractory rectal bleeding and clinical features consistent with radiation proctitis were reviewed. Treatment involved direct application of a 10 percent buffered formalin solution to the affected mucosa using a 16-inch cotton tip applicator applied through a proctoscope in the office setting. RESULTS: A total of 100 patients with a mean age of 75 (range, 49-91) years were followed for 18 (range, 1-79) months. The interval from radiation exposure to formalin treatment was 21 months. Overall, 93 percent of patients had cessation of bleeding after an average of 3.5 formalin applications at two-week to four-week intervals. Patients with severe (Grade 3) proctitis and those taking aspirin required an average of 1.5 additional treatments. A total of eight patients rebled at a mean of 24 months from treatment; however, all responded to further applications of formalin. Three patients complained of anal pain and one experienced dizziness postprocedure for a complication rate of 1.1 percent. CONCLUSIONS: We present a simple, cost-effective, and well-tolerated method of controlling hemorrhagic radiation proctitis. It is performed by using materials readily available in the office of a colon and rectal surgeon, eliminating the need for bowel preparation, anesthesia, or a surgical suite.

Administration, Rectal↗

Rectal microbicide acceptability: results of a volume escalation trial.

OBJECTIVES: The objectives of this study were to determine what volume of a microbicide placebo gel is acceptable when applied intrarectally before receptive anal intercourse (RAI); and to evaluate responses to properties of the gel, its application, and its use. STUDY DESIGN: HIV-uninfected men who reported unprotected RAI with serodiscordant or unknown-status partners were enrolled in a volume escalation trial. RESULTS: Up to 35 mL of gel with the physical properties of Femglide (transparent and odorless) was acceptable to the majority of participants. Choice of different levels of viscosity may be needed. For some men, volumes judged acceptable when tried without intercourse were not acceptable when used during sex. Overall, participants reported high intentions to use microbicides when available. Condom use was inconsistent despite advice to use condoms. CONCLUSIONS: Microbicides that would require up to 35 mL of volume to be effective would be acceptable to men who engage in high-risk RAI.

Administration, Rectal↗