PubMed · 10571920
Perfusion-based event-related functional MRI.
Abstract
Perfusion-based event-related functional MRI was performed by measuring flow-sensitive alternating inversion recovery (FAIR) signal changes during repeated single-trial, short visual stimulation (250 msec). In the visual cortex activation area, the blood flow increases immediately after the stimulus, reaches the maximum 4 sec later with a perfusion-sensitized signal change of 16. 1 +/- 2.6 %, and then decreases to baseline approximately 11 sec after the stimuli. As it is a more direct reflection of the hemodynamic response, perfusion-based event-related functional MRI techniques may be more useful for human cognitive function studies, compared with blood oxygenation level-dependent (BOLD)-based event-related functional MRI techniques. Magn Reson Med 42:1011-1013, 1999.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
H L Liu, J H Gao. 1999. Perfusion-based event-related functional MRI.. https://doi.org/10.1002/(sici)1522-2594(199912)42%3A6%3C1011%3A%3Aaid-mrm3%3E3.0.co%3B2-r