PubMed Health⌕ Search

PubMed · 10584329

High-throughput sample preparation and analysis using 96-well membrane solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of steroids in human urine.

Abstract

A 96-well solid-phase extraction (SPE) system is used to rapidly prepare human urine samples for high-throughput quantitative analysis of two steroids, equilenin and progesterone, by liquid chromatography-tandem mass spectrometry using deuterated estrone as the internal standard. We define high-throughput here as analysis of 384 samples in a 24 h period. A total of 384 samples and standards were extracted by an individual in one day and subsequently analyzed within a 24 h period. The inter- and intratray accuracy and precision obtained over the course of these injections was within 8% coefficient of variation when analyzed by atmospheric pressure chemical ionization mass spectrometry using positive ion detection. A semiautomated sample processing workstation was used to add internal standard and then process 96 samples at a time. The recovery of the analytes from the SPE was approximately 85%. The accuracy and precision obtained was comparable to that ordinarily obtained using manual sample preparation techniques.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Rule, J Henion. 1999. High-throughput sample preparation and analysis using 96-well membrane solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of steroids in human urine.. https://doi.org/10.1016/s1044-0305(99)00107-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High-throughput assay of oxygen radical absorbance capacity (ORAC) using a multichannel liquid handling system coupled with a microplate fluorescence reader in 96-well format.

The oxygen radical absorbance capacity (ORAC) assay has been widely accepted as a standard tool to measure the antioxidant activity in the nutraceutical, pharmaceutical, and food industries. However, the ORAC assay has been criticized for a lack of accessibility due to the unavailability of the COBAS FARA II analyzer, an instrument discontinued by the manufacturer. In addition, the manual sample preparation is time-consuming and labor-intensive. The objective of this study was to develop a high-throughput instrument platform that can fully automate the ORAC assay procedure. The new instrument platform consists of a robotic eight-channel liquid handling system and a microplate fluorescence reader. By using the high-throughput platform, the efficiency of the assay is improved with at least a 10-fold increase in sample throughput over the current procedure. The mean of intra- and interday CVs was <or=15%, and the limit of detection and limit of quantitation were 5 and 6.25 microM, respectively.

Autoanalysis↗

Automatic flow system with voltammetric detection for diacetyl monitoring during brewing process.

Diacetyl can be determined by adsorptive stripping voltammetry after derivatization with o-phenylenediamine. The method may be applicable to the determination of diacetyl in different foods, being a good alternative to other analytical methods. In this work an on-line automated analytical system for diacetyl determination in beer is described. A hanging mercury drop electrode voltammetric flow detector was used, and the analyte was determined without the traditional deoxygenation procedure. The method was successfully applied to the determination of diacetyl during beer fermentation and in the final product. The automation strategy used was based on a flow network similar to those used in multicommutated flow systems, with a pervaporation unit used for diacetyl separation. The developed system was tested in real conditions in the monitoring of brewing processes. The results obtained were similar to those obtained with the usual GC-ECD methodology in the 5-600 ppb range. The analytical rate of the developed method is about 12 determinations/h.

Autoanalysis↗