PubMed · 10591841

The Tromsø Study: artifacts in forearm bone densitometry--prevalence and effect.

Abstract

Suboptimal performance of bone densitometer, operator and/or subject may cause artifacts of consequence both for individual patient management and research. The prevalence and effects of such artifacts are largely unknown in densitometry. A cross-sectional population-based study was carried out of artifacts in forearm bone densitometry with single X-ray Absorptiometry (SXA) of the nondominant hand (distal and ultradistal site). After the screening, all scans were reviewed for artifact detection and reanalysis. The effect on the bone mineral density (BMD) result was found by comparing artifactual scans with a reanalyzed version or with normal repeat scans. All women aged 50-74 years, all men aged 55-74 years and 5-10% samples of other age groups aged >/=25 years attending the fourth Tromso health study were invited to have bone densitometry. The response rate from the background population was 80% (n = 7948). Fourteen percent of subjects had a movement artifact at either the distal or ultradistal site. The individual BMD variation was twice as large in scans with a movement artifact (0.94%) compared with normal scans (0.58%) (p = 0.0027). The radial endplate was inaccurately detected in 74% of the scans. Reanalysis of these scans led to a mean 3.8% decrease in the BMD value and an increase in the prevalence of osteoporosis of 10%. Artifacts were thus common, and their effects were clinically relevant in forearm bone densitometry. Artifacts and their effects need to be characterized in other bone densitometry settings also.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G K Berntsen, A Tollan, J H Magnus, A J Søgaard, T Ringberg, V Fønnebø. 1999. The Tromsø Study: artifacts in forearm bone densitometry--prevalence and effect.. https://doi.org/10.1007/s001980050249

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗