PubMed Health⌕ Search

PubMed · 10616816

The postoperative spine.

Abstract

During the last decade, magnetic resonance imaging (MRI) mostly has replaced computed tomography for evaluation of spinal surgery patients. The inherent advantages of MRI are obvious for this particularly difficult field of imaging. With MRI, it is possible to demonstrate anatomic as well as pathological and iatrogenic changes in three different imaging planes and countless neighboring planes and to obtain a superior view of the complex postoperative situation regardless of the spinal level imaged. Soft-tissue masses in particular can be identified more readily and located within three-dimensional space. One of the major advantages is that the nature and histology of the mass can be estimated precisely using different MR sequences in combination with intravenous contrast media. The most important benefit may be demonstration of inflammatory and hemorrhagic masses in the early postoperative periods (with special emphasis on alterations visible in the spinal cord itself) as well as repair processes and ongoing degeneration in later stages. This visualization is possible even when their extent is limited. In the postoperative spine, the application of MRI was facilitated with the advent of new materials, such as titanium alloys, used for surgical instrumentation. These new materials limit the amount of artifacts visible on MR images. Earlier implants made of other metallic material prohibit the use of computed tomography in the spine. This article provides a brief overview of the progress in spinal surgery and focuses on the developments in MRI techniques during the last decade. Technical questions about imaging of spinal instrumentation are discussed. "Normal" postoperative findings needed for interpretation of pathologic conditions are also discussed. Finally, the most important frequently asked questions from referring surgeons that radiologists must be able to answer by MRI are presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C B Henk, W Brodner, S Grampp, M Breitenseher, M Thurnher, G H Mostbeck, H Imhof. 1999. The postoperative spine.. https://doi.org/10.1097/00002142-199908000-00006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrochemical characterization of albumin protein on Ti-6AL-4V alloy immersed in a simulated plasma solution.

The effect of oxygen and albumin on the electrochemical behavior of a Ti-6Al-4V alloy immersed in a simulated inorganic plasma (SIP) solution was studied with a rotating-cylindrical electrode configuration to focus on the surface/electrolyte reactions. Potentiokinetic scans and electrochemical impedance spectroscopy have been used to characterize the interface by determining the passive current density and capacitance. For the polarization scans, an albumin addition of 37.7 mg/cm(3) to the SIP solution (oxygenated and unoxygenated) decreased the passive current density, indicating a lowering of the corrosive rate. The surface capacitance for the Ti-6Al-4V alloy immersed in a SIP solution averaged 13 microF/cm(2), which transformed after albumin addition (37.7 mg/cm(3)) from a potential independent behavior to the capacitance ranging from 23 to 6 microF/cm(2) with increasing potentials from -800 to 1500 mV(SCE), respectively, indicative of albumin adsorption. Within the same potential range and albumin addition to oxygenated solutions, the capacitances expanded slightly with a similar decreasing trend from 31 to 6 microF/cm(2), although the capacitance depicts an interaction between the hydrated passive film and the adsorbed albumin from -550 to 500 mV(SCE) in which the capacitance plateaued at 15 microF/cm(2). The hydrated porous oxide film results from the porous rutile layer reacting with H(2)O(2) formed as an intermediary component of oxygen reduction at the Ti-6Al-4V surface. The passive film-albumin interaction would affect the processing of titanium alloys in their surface preparation for biocompatibility, as well as determining the reactivity of titanium alloys to proteins.

Alloys↗

Fatigue-crack growth properties of thin-walled superelastic austenitic Nitinol tube for endovascular stents.

Over the past 10 years, the supereleastic nickel-titanium alloy Nitinol has found widespread application in the manufacture of small-scale biomedical devices, such as self-expanding endovascular stents. Although conventional stress/strain-life (S/N) analyses are invariably used as the primary method for design against fatigue loading and for predicting safe lifetimes, fracture mechanics-based methodologies provide a vital means of assessing the quantitative effect of defects on such lifetimes. Unfortunately, fracture mechanics studies on fatigue in Nitinol are scarce, and most results do not pertain to the (thin-walled tube) product forms that are typically used in the manufacture of endovascular stents. In the current work, we document the basic fatigue-crack growth properties of flattened thin-walled ( approximately 400 microm thick) Nitinol tubing in a 37 degrees C air environment. Crack-growth behavior is characterized over a wide range of growth rates ( approximately 6 orders of magnitude) and load ratios, that is, as a function of the alternating and maximum stress intensities, at 50 Hz. Limited experiments at both 5 and 50 Hz were also performed in 37 degrees C air and simulated body fluid to determine whether the cyclic frequency affects the fatigue behavior. Fatigue-crack growth-rate properties in such thin-walled Nitinol tube are found to be quite distinct from limited published data on other (mainly bulk) product forms of Nitinol, for example, bar and strip, both in terms of the relative fatigue thresholds and the variation in steady-state growth rates.

Alloys↗