PubMed Health⌕ Search

PubMed · 10626770

DNA sequencing using 96-capillary array electrophoresis.

Abstract

Practical DNA sequencing in a rugged capillary array electrophoresis system coupled directly to 96-well microtiter plates is demonstrated. A CCD detector was used to monitor all capillaries simultaneously with laser-induced fluorescence at 1.75 frames per second. The reconstructed electropherograms show good signal-to-noise ratios and resolution for the entire capillary array. The system used standard dye labeling and image splitting to obtain fluorescence intensities in two wavelength regions to allow calling up to 410 bases for the DNA sequence. The use of a replaceable poly(ethylene oxide) matrix and a protective poly(vinylpyrrolidone) coating allows high separation speed and short turnaround time for high throughput DNA sequencing. Critical evaluation of the system performance over repeated runs with base calling is presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Pang, V Pavski, E S Yeung. 1999-11-30. DNA sequencing using 96-capillary array electrophoresis.. https://doi.org/10.1016/s0165-022x(99)00042-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New concepts to improve resolution and sensitivity of molecular cytogenetic diagnostics by multicolor fluorescence in situ hybridization.

BACKGROUND: Routine application of multicolor fluorescence in situ hybridization (M-FISH) technology for molecular cytogenetic diagnostics has been hampered by several technical limitations. First, when using chromosome-specific painting probes, there is a limit in cytogenetic resolution of approximately 2-3 Mb, which can mask hidden structural abnormalities that have a significant clinical effect. Second, using whole chromosome painting probes, intrachromosomal rearrangements cannot be detected and the exact localization of breakpoints is often not possible. METHODS: We suggest the use of multiplex-labeled region or locus- specific probes in combination with an optimal probe design to improve the sensitivity and resolution of the M-FISH technology. To allow the application of this assay in routine diagnostics, we developed a multipurpose image analysis system. RESULTS: goldFISH was applied to the study of cryptic translocations in mental retardation patients and to the study of high-resolution breakpoint mapping in non-small cell lung cancer patients. For an individual with mental retardation, who had an apparently normal karyotype by G-banding, we detected an unbalanced translocation involving chromosomes 2 and 7. CONCLUSIONS: In combination with optimally designed probe kits, goldFISH overcomes most of the present limitations of the M-FISH technology and results in virtually 100% reliability for detecting interchromosomal and intrachromosomal rearrangements.

Automation↗

X-LIGAND: an application for the automated addition of flexible ligands into electron density.

With the advent of drug-design experiments where the interaction between a protein and a ligand is determined using X-ray crystallography, the use of automated methods for modelling the ligand into electron density represents a powerful tool. Once the protein structure has been determined by crystallography it is normal that subsequent ligand-complex structures are isomorphous, or nearly so, with the original structure and it is necessary only to determine the fit of ligand to any unsatisfied electron density. The X-LIGAND application was designed with this protocol in mind and provides a tool that searches for unsatisfied electron density and then fits flexible ligands to this within minutes without user intervention.

Automation↗

3'-nitrophenylpropyloxycarbonyl (NPPOC) protecting groups for high-fidelity automated 5' --> 3' photochemical DNA synthesis.

[structure: see text]. The most powerful DNA microarrays would be prepared by photolithography with free 3'-ends that could be processed enzymatically. A photoremovable group that could be removed in quantitative yield would ensure high purity of the synthesized probes. We have developed new pyrimidine building blocks for 5' --> 3' DNA synthesis with high cycle yields using the NPPOC (3'-nitrophenylpropyloxycarbonyl) protecting group. These phosphoramidites were proved in automated photochemical DNA synthesis on a modified synthesizer.

Automation↗