PubMed Health⌕ Search

PubMed · 10652007

Multiple frequency fluorescence lifetime imaging microscopy.

Abstract

The experimental configuration and the computational algorithms for performing multiple frequency fluorescence lifetime imaging microscopy (mfFLIM) are described. The mfFLIM experimental set-up enables the simultaneous homodyne detection of fluorescence emission modulated at a set of harmonic frequencies. This was achieved in practice by using monochromatic laser light as an excitation source modulated at a harmonic set of frequencies. A minimum of four frequencies were obtained by the use of two standing wave acousto-optic modulators placed in series. Homodyne detection at each of these frequencies was performed simultaneously by mixing with matching harmonics present in the gain characteristics of a microchannel plate (MCP) image intensifier. These harmonics arise as a natural consequence of applying a high frequency sinusoidal voltage to the photocathode of the device, which switches the flow of photoelectrons 'on' and 'off' as the sinus voltage swings from negative to positive. By changing the bias of the sinus it was possible to control the duration of the 'on' state of the intensifier relative to its 'off' state, enabling the amplitude of the higher harmonic content in the gain to be controlled. Relative modulation depths of 400% are theoretically possible from this form of square-pulse modulation. A phase-dependent integrated image is formed by the sum of the mixed frequencies on the phosphor of the MCP. Sampling this signal over a full period of the fundamental harmonic enables each harmonic to be resolved, provided that the Nyquist sampling criterion is satisfied for the highest harmonic component in the signal. At each frequency both the phase and modulation parameters can be estimated from a Fourier analysis of the data. These parameters enable the fractional populations and fluorescence lifetimes of individual components of a complex fluorescence decay to be resolved on a pixel-by-pixel basis using a non-linear fit to the dispersion relationships. The fitting algorithms were tested on a simulated data set and were successful in disentangling two populations having 1 ns and 4 ns fluorescence lifetimes. Spatial invariance of the lifetimes was exploited to improve the accuracy significantly. Multiple frequency fluorescence lifetime imaging microscopy was then successfully applied to resolve the fluorescence lifetimes and fluorescence intensity contributions in a rhodamine dye mixture in solution, and green fluorescent protein variants co-expressed in live cells.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Squire, P J Verveer, P I Bastiaens. 2000. Multiple frequency fluorescence lifetime imaging microscopy.. https://doi.org/10.1046/j.1365-2818.2000.00651.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fluorescence of fungi in superficial and deep fungal infections.

BACKGROUND: Fluorescence of many fungi is noted when H&E stained sections are examined under a fluorescent microscope. In theory, this phenomenon could aid in the diagnosis of cutaneous and disseminated fungal infections without the delay associated with special stains. Seventy-six cases of superficial and deep fungal infections and 3 cases of protothecosis were studied to determine the clinical usefulness of this technique. RESULTS: In most cases, fluorescence was noted, but was not intense. Fluorescence of fungi did not correlate with the age of the specimen. In most cases, organisms in H&E stained sections were more easily identified with routine light microscopy than with fluorescent microscopy. CONCLUSION: This report suggests that in H&E stained skin specimens, fluorescent microscopy is of little benefit in the identification of fungal organisms.

Fluorescence↗

Use of a green fluorescent protein gene as a reporter in Zymomonas mobilis and Halomonas elongata.

We investigated the applicability of the green fluorescent protein of Aequorea victoria as a reporter for gene expression in the strictly fermentative Gram-negative ethanologenic bacterium Zymomonas mobilis and in the moderately halophilic bacterium Halomonas elongata. We have succeeded to express a mutated gene of green fluorescent protein under the control of different promoters in Z. mobilis and H. elongata grown under various glucose or salt concentrations, respectively. Our results demonstrate that gfp can serve as an easily assayable reporter gene in both organisms. Maximum fluorescence was obtained in Z. mobilis grown aerobically and in H. elongata grown under elevated salt concentration in solid medium. For both bacteria the fluorescence obtained was higher when the gfp gene was placed under the control of a native promoter.

Fluorescence↗

A fluorescence-based assay for transcription using a novel fluorescent GTP analogue.

A new fluorescent analogue of GTP (Cm-GTP) was synthesized, which contained a coumarin fluorophore attached to the gamma phosphorus. This compound was tested in transcription assays using T7 RNA polymerase as a model system. The fluorescent nucleotide was incorporated specifically at the 5' end of nascent RNA synthesized in two different modes of transcription initiation. In the first mode, with only Cm-GTP (+GTP), reiterative slippage synthesis occurred and poly rG ladders of up to 14 nucleotides were synthesized. In the second mode, with Cm-GTP (+GTP)+ATP+CTP, abortive transcripts of up to seven or eight nucleotides were synthesized. The fluorescence properties of the two types of RNA were studied in detail. There was greater reduction in fluorescence intensity in G-ladders than in abortive transcripts. Steady-state anisotropy and anisotropy decay indicated that the fluorophore motion was constrained in G-ladder RNAs as compared to abortive RNAs. Quenching experiments by using extraneous quenchers showed that the excited state of fluorophore at the 5' end of G-ladder RNA was less efficiently quenched as compared to the free fluorophore. These studies suggested that the fluorescent GTP analogue sensed the structural features that distinguished G-ladder RNAs from abortive RNAs. The results suggested that G-ladder RNAs adapt unusual conformations such as G-quartets. Thus, the new fluorescent probe can be useful for structural studies on RNA.

Fluorescence↗