PubMed · 10664725

Imaging for cochlear implants.

Abstract

All patients in the Birmingham Cochlear Implant Programme underwent computerized tomography (CT) scanning and were assessed and images interpreted by the main author. Of the first 100 cases, 20 were considered to have abnormalities of the inner ears by CT imaging. It is concluded that the commonest abnormality was cochlear otospongiosis followed by labyrinthitis ossificans. Otospongiosis is well shown by CT which gives a good predicator of luminal patency. However, labyrinthus obliterans, although usually apparent on CT, is not reliably shown in all cases and T2 weighted magnetic resonance imaging (MRI) is better.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P D Phelps, D W Proops. 1999. Imaging for cochlear implants.. https://pubmed.ncbi.nlm.nih.gov/10664725/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cochlear implant failure: imaging evaluation of the electrode course.

Cochlear implant (CI) is an electronic device used to rehabilitate patients with sensorineural hearing loss. The intent of this review is to demonstrate the normal position of the electrode on computed tomography (CT) and contrast this with various examples of the electrode malpositioning. Post-implantation CT is performed to localize the cause of implant failure in patients in which radiographs suggest an anomalous course of the electrode. A common cause of device failure is extrusion or malpositioning of the electrode. It is important for the radiologists to recognize this important aspect of device failure. Post-implant CT can help identify patients with malpositioned electrode in whom another attempt can be made by correctly re-implanting the electrode.

Cochlea↗

Identification of hearing loss in newborns by transient otoacoustic emissions.

OBJECTIVE: More than 90% of congenital hearing loss cases are of cochlear origin. There are two methods for newborn hearing screening: the transient otoacoustic emission (TEOAE) or (ABR) screening. When TEOAE is used for hearing screening patients, newborn with a neural hearing loss are not discovered. MATERIALS: In the present study TEOAEs were obtained from 3,048 newborns from both ears in patients with and without risk factors for hearing loss in the history. All newborns who did not pass TEOAE in the 2nd screening (uni or bilaterally) underwent additional audiologic tests. RESULTS: In the first screening 150 (4.5%) of the newborns newborn did not pass the screening and 30 (0.98%) did not pass in the second screening. In nine newborns with unilateral absent TEOAE and in two newborns a deafness was confirmed, with one side cochlear and on the other side retrocochlear. Both patients received cochlear implants before the 2nd year of age. In 21 newborns with absent TEOAE bilaterally, five had moderate sensorineural hearing loss bilaterally and in nine patients profound hearing loss (90-100 dB) or deafness was confirmed. Of 3,048 newborns there were 1,355 with a risk of hearing loss and in 12 (0.88%) newborns bilateral hearing loss or deafness was confirmed; of the 1663 newborns without risk of hearing loss in the history, in four (0.24%) newborn deafness or bilateral sensorineural hearing loss in the range of 45-65 dB were confirmed. CONCLUSION: When the newborn has an absent TEOAE uni or bilaterally, we need to inform the parents and to recommend additional screening and other audiologic tests to confirm or exclude hearing loss.

Cochlea↗

Evaluation of trajectories and contact pressures for the straight nucleus cochlear implant electrode array - a two-dimensional application of finite element analysis.

A two-dimensional (2D) finite element analysis has been used in this study to model the insertion of the Nucleus electrode array with different stiffness properties in order to evaluate the propensity of damage by visualizing the predicted trajectories and by comparing the buckling stresses and the contact pressures at the tip (and its distribution along the length) of the electrode array. Previous temporal bone studies have shown that damage during insertion of an electrode array around the basal turn of the cochlear spiral could be related to the design and the stiffness properties of the electrode array. However, it is difficult to evaluate different designs of electrode arrays purely by experimental methods as the experimental conditions and their results are difficult to reproduce. Three electrode arrays with different mechanical properties, i.e. uniform stiffness, graded stiffness, and a soft tip have been modelled. Buckling stress and contact pressure at the tip of the electrode array were found to be highest for the arrays with uniform stiffness. The contact pressures at the tip of the electrode array appeared strongly influenced by the stiffness profile and were optimal for graded stiffness. The results indicate the importance of the electrode array design and stiffness properties in minimizing trauma. However, there are a number of limitations in the present 2D evaluation which will require further analysis using a three-dimensional model to obtain definitive results.

Cochlea↗