Abstract

The search for the ideal bone substitute began hundreds of years ago, and continues today. While numerous choices have been proposed and tested, with varying degrees of success, there remain many challenges related to the use of bone substitutes in craniofacial reconstruction. This paper presents a review of the history of bone substitute research, a discussion of currently popular materials, and elucidation of the challenges to be faced as we approach the new millennium.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F D Burstein. 2000. Bone substitutes.. https://doi.org/10.1597/1545-1569_2000_037_0001_esntit_2.3.co_2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Hydroxyapatite coating on titanium by thermal substrate method in aqueous solution.

A new hydrocoating method (the thermal substrate method) is proposed for coating calcium phosphates such as hydroxyapatite (HA), on titanium substrates in an aqueous solution. Several factors (e.g., the type of ion source, the heating time and temperature, and the surface roughness of the substrate) affected the characteristics of the precipitate formed by this method. The solution used included 3 mmol dm(-3) Ca(H(2)PO(4))(2) and 7 mmol dm(-3) CaCl(2), and its pH was adjusted to 6.5. The experimental studies were conducted under the following conditions: temperature 45-160 degrees C, heating time 10-20 min, and surface roughness of substrate #120-#2000 grid ground using energy paper. A high quality of precipitate, whose predominant component was HA, was obtained on titanium substrates by the thermal substrate method in an aqueous solution. No significant difference in the precipitates was found with the type of ion source. The amount of HA precipitate increased with increasing temperature and with increasing heating time. The features of the precipitate were different, depending on the surface roughtness of the substrate: HA regularly nucleated along the grooves of the rough surface (#120 and #400 grid), and in the case of the fine surface (#1200-#2000 grid), a uniform precipitation occurred.

Biocompatible Materials↗

In vitro stability of a novel compliant poly(carbonate-urea)urethane to oxidative and hydrolytic stress.

Poly(ester)urethane and poly(ether)urethane vascular grafts fail in vivo because of hydrolytic and oxidative degradative mechanisms. Studies have shown that poly(carbonate)urethanes have enhanced resistance. There is still a need for a viable, nonrigid, small-diameter, synthetic vascular graft. In this study, we sought to confirm this by exposing a novel formulation of compliant poly(carbonate-urea)urethane (CPU) manufactured by an innovative process, resulting in a stress-free. Small-diameter prosthesis, and a conventional poly(ether)urethane Pulse-Tec graft known to readily undergo oxidation in a variety of degradative solutions, and we assessed them for the development of oxidative and hydrolytic degradation, changes in elastic properties, and chemical stability. To simulate the in vivo environment, we used buffered solutions of phospholipase A(2) and cholesterol esterase; solutions of H(2)O(2)/CoCl(2), t-butyl peroxide/CoCl(2) (t-but/CoCl(2)), and glutathione/t-butyl peroxide/CoCl(2) (Glut/t-but/CoCl(2)); and plasma fractions I-IV, which were derived from fresh human plasma centrifuged in poly(ethylene glycol). To act as a negative control, both graft types were incubated in distilled water. Samples of both graft types (100 mm with a 5.0-mm inner diameter) were incubated in these solutions at 37 degrees C for 70 days before environmental scanning electron microscopy, radial tensile strength and quality control, gel permeation chromatography, and in vitro compliance assessments were performed. Oxidative degradation was ascertained from significant changes in molecular weight with respect to a control on all Pulse-Tec grafts treated with t-but/CoCl(2), Glut/t-but/CoCl(2), and plasma fractions I-III. Pulse-Tec grafts exposed to the H(2)O(2)/CoCl(2) mixture had significantly greater compliance than controls incubated in distilled water (p < 0.001 at 50 mmHg). No changes in molecular weight with respect to the control were observed for the CPU samples; only those immersed in t-but/CoCl(2) and Glut/t-but/CoCl(2) showed an 11% increase in molecular weight to 108,000. Only CPU grafts treated with the Glut/t-but/CoCl(2) mixture exhibited significantly greater compliance (p < 0.05 at 50 mmHg). Overall, results from this study indicate that CPU presents a far greater chemical stability than poly(ether)-urethane grafts do.

Biocompatible Materials↗

Interface-mediated synthesis of hydroxyapatite.

Interfacing of water vapor and titanium was employed for a controlled synthesis of surface-supported hydroxyapatite. In this approach, a Ti surface was doped with Ca and P by ion implantation and then subjected to a hydrothermal treatment in a water vapor autoclave. Ion implantation served to prepare a reactive blend of finely dispersed reactants in a stoichiometric ratio incorporated within the network of an outermost layer of the substrate surface. Needle-like carbonate hydroxyapatite in an overlay was identified to deposit onto the surface. The results suggest interface-mediated thin film formation and phase transformation.

Biocompatible Materials↗