PubMed Health⌕ Search

PubMed · 10691249

Erroneous conclusion from processed electroencephalogram with changing anesthetic depth.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E J Heyer, D C Adams, C Moses, D O Quest, E S Connolly. 2000. Erroneous conclusion from processed electroencephalogram with changing anesthetic depth.. https://doi.org/10.1097/00000542-200002000-00044

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Nicorandil accelerates recovery of neuromuscular block caused by vecuronium.

PURPOSE: To examine the effect of nicorandil, a K ATP channel agonist, on neuromuscular block caused by vecuronium in patients anesthetized with nitrous oxide, oxygen, isoflurane, and fentanyl. METHODS: Sixty adult patients were allocated to four groups of 15: nicorandil-post-tetanic count (N-PTC), nicorandil-train-of-four (N-TOF), control-post-tetanic count (C-PTC) or control-train-of-four (C-TOF) group. In the N-PTC and N-TOF groups, 0.1 mg kg nicorandil was given as a bolus followed by an infusion at 1 microg x kg(-1) x min(-1). Two minutes after the bolus, 0.1 mg x kg(-1) vecuronium was administered. In the C-PTC or C-TOF group normal saline was given instead of nicorandil. PTC and TOF responses were measured mechanically using a force displacement transducer. RESULTS: Time from the administration of vecuronium to the onset of neuromuscular block in the N-PTC or N-TOF group did not differ from that in the C-PTC or C-TOF group (241 +/- 33 vs 225 +/- 32 sec, mean +/- SD). Times from vecuronium injection to the return of PTC in the N-PTC and C-PTC groups, and those of T1, T2, T3, and T4 (first, second, third, and fourth stimulation of TOF) in the N-TOF and C-TOF groups did not differ. Recoveries of PTC in the N-PTC and C-PTC groups followed similar time course. T1/control twitch height and TOF ratio (T4/T1) in the N-TOF group were higher than those in the C-TOF group 80-120 min and 100-120 min after administration of vecuronium, respectively. CONCLUSION: Nicorandil accelerates recovery of neuromuscular block caused by vecuronium.

Anesthesia, Inhalation↗

[Epileptoform EEG activity: occurrence under sevoflurane and not during propofol application].

In a 62-year-old female patient without a history of epileptic seizures EEG monitoring (EEG monitor: Narcotrend) was routinely performed during propofol/remifentanil and during sevoflurane/remifentanil/nitrous oxide anaesthesia. In the first course of anaesthesia after a bolus of propofol 1% a continuous EEG slowing was followed by a burst suppression pattern without occurrence of epileptiform activity throughout this sequence. During the second course of anaesthesia the sevoflurane concentration was increased from 2 to 8 % by volume. After 5 min epileptiform activity appeared in the EEG at an endtidal concentration of 5.9% by volume.

Anesthesia, Inhalation↗

[Low alkali-hydroxide content in soda limes does not lead to reduction of compound A formation from sevoflurane during low-flow anesthesia].

The alkali hydroxide content in soda lime induces Compound A formation from Sevoflurane (Sevo). This study was designed to answer the question if the use of potassium hydroxide-free Soda Lime (SL) would lead to lower Compound A levels as compared to Sodasorb (SO). A total of 30 patients scheduled for elective laparoscopic cholecystectomy received Sevo anaesthesia under low-flow conditions (0.8 l/min fresh gas flow). Each absorbent was used in 15 patients, but 3 patients of the SO group were excluded due to technical problems with Compound A analysis. Hemodynamic parameters, parameters of ventilation and gas concentrations were documented. Compound A concentrations were measured by gas chromatography from gas samples before Sevo application and 20, 40, 60, 90 and 120 min after low-flow start. Mean endtidal Sevo concentrations were 1.94 +/- 0.17 (SO) and 1.97 +/- 0.15 (SL) vol %, the total anaesthetic exposition was 1.52 +/- 0.36 (SO) and 1.64 +/- 0.47 (SL) MAC-h (n.s). The maximum Compound A concentration was significantly higher in SL group (19.6 +/- 2.8 vs. 11.7 +/- 4.1 ppm, p < 0.001). Therefore, elimination of potassium hydroxide from carbon dioxide absorbents alone did not lead to a reduction of Compound A formation during low-flow anaesthesia.

Anesthesia, Inhalation↗