Immunoplatelet counting: a proposed new reference procedure.

Abstract

Given the high degree of interoperator error and poor precision of manual platelet counting, it has recently been proposed that an immunoplatelet counting method could become the new reference procedure. Platelets are identified immunologically with a suitable monoclonal antibody, and the platelet count is derived from the ratio of fluorescent platelet events to collected red blood cell (RBC) events that are also counted by a reliable and calibrated standard impedance counter (RBC ratio). In this study, we have set up a rapid and simple method for immunoplatelet counting and simultaneously compared the RBC ratio with the bead ratio derived from two different preparations of commercial calibration beads (Trucount and FlowCount beads). Comparison of the level of imprecision of the RBC ratio with either the manual count or bead ratios revealed a superior coefficient of variation of < 5% even in samples with a platelet count < 20 x 10(9)/l. The RBC ratio correlated extremely well with the existing manual phase reference method (r2 = 0.93) and especially well with three different commercial impedance counters and a dual-angle optical counter (r2 = 0.98-0.99). However, at < 100 x 10(9)/l, the correlation of the RBC ratio with the dual-angle optical count (ADVIA 120) (r2 = 0.96) was superior to all impedance counters. This suggests that automated optical counting methods may be more accurate at determining platelet counts in thrombocytopenic samples. As the RBC ratio is rapid, cheap and relatively easy to perform, we propose that this method could replace the manual count as a new international reference method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Harrison, A Horton, D Grant, C Briggs, S MacHin. 2000. Immunoplatelet counting: a proposed new reference procedure.. https://doi.org/10.1046/j.1365-2141.2000.01846.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗