PubMed Health⌕ Search

PubMed · 10695330

[Endoscopic endonasal surgery with image-guidance].

Abstract

We evaluated the advantages and disadvantages of image-guided endoscopic endonasal surgery for various diseases. Thirty-three patients, including 8 with chronic sinusitis, 14 with paranasal cysts, 1 with paranasal tumor (biopsy), 1 with sellaturcial cyst (Rathke's cleft cyst) and 9 with pituitary tumors were endonasally operated on from September 1998 to May 1999, with an electromagnetic navigation system, The Insta Trak (Visualization Technology Inc. USA). The Insta Trak system is composed of a computer, a metal probe with a nonmetallic suction tube attachment, and a soft-type headset with an electromagnetic sensor. This freehand, armless system compensates well for patient's head movement during surgery, and precludes the need for head fixation. Either straight or curved suction tube (probe) can be used to access almost of all pathological sites in the sinus cavity. Location of the metal probe is displayed on the computer moniter as an intersection point on the axial, coronal and sagital CT images. In all cases, Insta Trak showed the surgeon the appropriate location and direction of each lesion. The Insta Trak also indicated the location of the orbit, optic canal, nasolacrimal duct and/or skull base, thus, preventing intraoperative complications. When the anatomy was distorted by previous surgery and/or when there was uncontrollable bleeding from a severe lesion so that the surgeon had difficulty finding the proper orientation, the usefulness of image-guided surgery was sufficiently recognized. However, the following disadvantages were also pointed out. An additional 15 to 20 minutes is needed for equipment set up and operation, unless the surgeon and the operation room staff are familiar with the machine. The patient's CT image used for navigation relies on data obtained preoperatively, that is to say, it can not reflect morphological changes produced during surgery. Moreover, the surgeon must consider possible errors of the navigational point that may result in the headset during surgery, as well as, errors the machine may originally possess. The image-guided system successfully integrated the most up-to-date computer technology with a surgeon's anatomical knowledge for improved treatment of endoscopic endonasal surgery. However, we also concluded that the system should be used as a surgical supporting device for safer and more adequate procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Otori, S Haruna, M Yoshiyuki, H Moriyama. 2000. [Endoscopic endonasal surgery with image-guidance].. https://doi.org/10.3950/jibiinkoka.103.1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Training with simulation improves residents' endovascular procedure skills.

BACKGROUND: Endovascular procedure simulators are now commercially available and in use for physician training. The purpose of this study was to evaluate the role of simulation-based training in vascular surgery residencies. METHODS: Residents from vascular surgery programs in a five-state area were invited to participate in a series of 2-day endovascular training programs that used a high-fidelity endovascular procedure simulator (SimSuite; Medical Simulation Corporation, Denver, Colo), didactic instruction, computer-based training, and tabletop procedure demonstrations. The curriculum covered arteriography and intervention for treatment of aortoiliac, renal, and carotid artery disease. Nine residents participated, with one to three per training session. Each completed an average of 9.5 simulated endovascular cases. Performance on a standardized TransAtlantic Inter-Society Consensus B iliac angioplasty/stenting case was used to assess endovascular skills and knowledge at the beginning of the training program, and this was repeated at the completion of the training. Performance metrics were measured by the simulator, faculty observed trainees' performance of simulated cases, and trainees provided their evaluations of the usefulness of the simulation experiences. RESULTS: Endovascular procedural skills on the standardized iliac intervention case improved after completion of the training program. Compared with performance early on day 1, performance improved (P < or = .05; paired t test): total procedure time decreased 54%, volume of contrast decreased 44%, and fluoroscopy time decreased 48% (mean change from baseline). Selection of angioplasty balloon catheters and stents was improved, and the average number of catheters used and stents deployed decreased, although this did not reach statistical significance. Faculty observation allowed identification of shortcomings of knowledge and skills, including common problems with selection of catheter, balloon, and stent sizes; correct positioning of the sheath; and intraprocedural monitoring. Postcourse evaluations indicated support for the use of simulation in vascular surgery residents' endovascular training. CONCLUSIONS: Training with a simulator, incorporated into an individual or small group learning session, offers a means to learn and realistically practice endovascular procedures without direct risk to patients, with measurable improvements in key performance metrics. How simulation training affects subsequent clinical performance has yet to be established.

Endoscopy↗

Intraoperative surgical navigation for endoscopic sinus surgery: rationale and indications.

PURPOSE OF REVIEW: The present review discusses the rationale and indications for image-guided surgery through a critical discussion of registration concepts as well as clinical reports. RECENT FINDINGS: The surgical navigation accuracy achieved by commercially available image-guided surgery systems is best reported as target registration error. Clinically achievable target registration error is probably in the 1.5-2.0 mm range. Dry lab studies of registration serve to highlight the principles of registration, the process through which image-guided surgery systems calculate the one-to-one mapping relationship between the preoperative imaging data and the intraoperative surgical volume. Reports on image-guided surgery have highlighted its usefulness in primary and revision endoscopic sinus surgery, osteoplastic frontal sinusotomy, transsphenoidal hypophysectomy, endoscopic cerebrospinal fluid leak repair and endoscopic pterygomaxillary fossa biopsy. Both three-dimensional computed tomography angiography and computed tomography-magnetic resonance fusion images have been incorporated into IGS for advanced minimally invasive endoscopic skull base procedures. The American Academy of Otolaryngology-Head and Neck Surgery policy statement accurately summarizes the current consensus for image-guided surgery applications. SUMMARY: Image-guided surgery has emerged as an important technology, which both general otolaryngologists and subspecialty rhinologists can employ for a wide variety of procedures.

Endoscopy↗