Wear behavior of precision attachments.

Abstract

PURPOSE: The purpose of this article was to compare the wear behavior of precision attachments with plastic inserts to conventional metal-alloy precision attachments. MATERIALS AND METHODS: In a comparative study attachments of various designs were subjected to alternating load cycles in a wear simulator. In addition to conventional adjustable attachments with metal-alloy matrix and patrix elements, attachments with female elements that are lined with plastic inserts were investigated for the first time. In each wear test 10,000 separating and joining movements were performed in an axial direction under a continuous spray of artificial saliva at 37 degrees C. RESULTS: The attachments with metal surfaces showed a rapid loss of approximately 60% of the required separating/joining forces during the first 1,000 cycles; after a further 9,000 cycles these forces fell to 25% and 35%, respectively, of the initial value. The attachments with plastic inserts, by contrast, showed only a 4% and 8% loss, respectively, of the required separating/joining forces even after 10,000 wear cycles. With one attachment type a reproducible 20% increase of retention occurred during the testings. CONCLUSION: The precision attachments with plastic female inserts showed only negligible amounts of wear and the most consistent retentive force in comparison with conventional precision attachments consisting of metal-alloy matrix and patrix components.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M G Wichmann, W Kuntze. Wear behavior of precision attachments.. https://pubmed.ncbi.nlm.nih.gov/10709521/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of variations from the recommended powder/liquid ratio on some properties of resin-modified cements.

OBJECTIVES: The powder and liquid contents of cements are mixed in accordance with the recommended mixing ratio, but discrepancies occur despite the use of proportioning scoops. Little is known about powder/liquid ratio variations on certain properties of resin-modified cements. METHODS: Two resin-modified glass ionomer cements (RMGIC) were mixed using various powder/liquid ratios: (a) Recommended ratio: Fuji Plus: powder/liquid 2:1; ProTecCEM p/l 2.25:1. (b) Maximal variation arising using proportioning aids (17% liquid surplus): Fuji Plus 1.66:1, ProTecCEM 1.875:1. Limits of mixing and specimen construction: either (c) both groups with more liquid (1.5:1) or (d) more powder (3:1). Flexural strength was determined using a 3-point bending test (after 24 h) and wear using a 3-body abrasion device. The extent of cure reaction was characterized using differential thermal analysis (DTA). RESULTS: While higher powder content did not significantly affect the flexural strength of Fuji Plus and ProTecCEM, it considerably reduced wear of Fuji Plus. Increasing liquid content reduced flexural strength. A substantial increase in wear for Fuji Plus 1.5:1, and ProTecCEM 1.875:1 and 1.5:1 mixtures was observed. DTA demonstrated that a higher liquid content resulted in incomplete setting reactions, which could be detected even after 24 h of cure. CONCLUSIONS: If RMGICs are mixed with powder/liquid variations, given the inaccuracy of proportioning aids the properties of RMGIC will change slightly and may be disregarded. If set with higher powder/liquid variations, a surplus of powder has less influence on the properties than a surplus of liquid.

Dental Restoration Wear↗

Wear and superficial roughness of glass ionomer cements used as sealants, after simulated toothbrushing.

The purpose of this study was to evaluate, in vitro, the properties (wear and roughness) of glass ionomer cements that could influence their indication as pit and fissure sealants. The utilized materials were Fuji Plus, Ketac-Molar and Vitremer (in two different proportions: 1:1 and :1). The resin-based sealant Delton was used as control. By means of an electronic balance (precision of 10-4 g), wear was measured in function of weight loss after simulated toothbrushing. Superficial roughness was determined by means of a surface roughness-measuring apparatus. The results revealed that diluted Vitremer and Fuji Plus were less resistant to toothbrushing abrasion and had the greatest increase in superficial roughness. Although in clinical situations luting or diluted ionomer cements are often utilized as alternatives to resin-based sealants, the resultsof this study revealed that the properties of those cements are worse than those of restorative ionomers, whichpresented results similar to those of the evaluated resin sealant.

Dental Restoration Wear↗

Physico-mechanical properties of a fast-set highly viscous GIC restorative.

UNLABELLED: The fast-setting reaction of 'fast-set' highly viscous glass-ionomer cements (GIC) may result in superior mechanical properties and good wear resistance as the material can theoretically achieve sufficient strength to resist masticatory loads within a shorter time. The aim of this study was to determine the hardness, strength (compressive and diametral tensile) and wear resistance of a 'fast-set' highly viscous GIC (Fuji IX GP Fast). Its regular set counterpart (Fuji IX GP) was used for comparison. The glass powders of the two cements were also characterized. Hardness testing [Vickers' hardness number (VHN)] was performed with a digital hardness tester (load=50 g; dwell time=30 s) and compressive/diametral tensile strength testing (MPa) was conducted based upon British Standards specification for GICs (BS6039, 1981). Wear testing was conducted using a reciprocal compression-sliding wear instrumentation at 20 MPa contact stress against SS304 counter-bodies with distilled water as lubricant. All specimens were immersed in distilled water at 37 degrees C and tested 24 h after start of mixing. Further mechanical tests (hardness and strength) were conducted with specimens stored for 1 week in distilled water at 37 degrees C. The glass powders were characterized using laser particle sizing, standard electron microscope (SEM) and energy dispressure X-ray (EDX) analysis. Results were analysed using multiple analysis of variance (manova) and independent samples t-test at significance level 0.05. No significant difference in hardness, compressive and diametral tensile strength was observed between Fuji IX GP and Fuji IX GP Fast at 1 day. There was also no significant difference in wear at all cyclic intervals. Although the difference in strength was not significant between the two cements at 1 week, Fuji IX GP Fast was significantly harder than Fuji IX GP. Particle size of both cements ranged from 0.3 to 200 microm. The mean particle sizes were, however, different and were 13.43 and 7.13 microm for Fuji IX GP and Fuji IX GP Fast, respectively. Fuji IX GP Fast offers no other advantage over Fuji IX GP with the exception of improved hardness. CLINICAL RELEVANCE: Besides being harder, the fast-set highly viscous GIC restorative offers no other physico-mechanical advantage over its regular set counterpart.

Dental Restoration Wear↗