Alveolar bone response to submerged bisphosphonate-complexed hydroxyapatite implants.

Abstract

BACKGROUND: In most studies using submerged hydroxyapatite implants, maintenance of alveolar bone after tooth extraction was attempted with plain hydroxyapatite materials. However, clinical results have shown that hydroxyapatite may require biological modification with a bone resorption-inhibiting agent which may be beneficial for maintenance of alveolar bone. We conducted experimental and clinical studies to evaluate the effect of highly bisphosphonate-complexed hydroxyapatite implants on osteoconduction and repair in alveolar bone. METHODS: Porous hydroxyapatite implants were pre-incubated in 10(-2)M bisphosphonate solutions at pH 3.49. The implants had a diameter of 2.1 mm and a height of 2 mm and adsorbed 115 microg bisphosphonate. Five goats were implanted with 4 plain hydroxyapatite implants on each side of the mandible in root extraction sockets for the precision analysis of dual x-ray absorptiometry (DEXA) measurements. Ten goats were implanted with 4 bisphosphonate/hydroxyapatite implants on one side of the mandible and 4 plain hydroxyapatite implants on the opposite mandible. In a clinical study, 23 bisphosphonate/hydroxyapatite implants were placed in periodontally destroyed tooth root sockets and followed up during one year. RESULTS: The range for the bone mineral density (BMD) measurement errors for goat histologic sections was 0.48% to 1.03%. There were large differences in peri-implant BMDs in the left and right mandible of the same goat, irrespective as to whether hydroxyapatite or bisphosphonate/hydroxyapatite implants were present. This was due to local anatomical differences typical of alveolar bone. These differences were not significant. Histologically, all bisphosphonate/hydroxyapatite as well as hydroxyapatite controls appeared to be fully integrated and effective as bone replacement material in goat alveolar bone. They exhibited vascularization and osteoconduction of alveolar bone growth along and inside their porous structure. In patients peri-implant healing was clinically and radiographically comparable to plain hydroxyapatite implants. All implants were retained and no dehiscences developed. Radiographically, peri-implant radiolucencies disappeared and alveolar bone was deposited in close proximity to the implants. CONCLUSIONS: This study contributes to the understanding of the biological properties of hydroxyapatite implants as carriers for the bone-modulating agent bisphosphonate. Our study suggests that normal osteoconduction and repair occurred in alveolar bone around the highly bisphosphonate-complexed hydroxyapatite implants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Denissen, C Montanari, R Martinetti, A van Lingen, A van den Hooff. 2000. Alveolar bone response to submerged bisphosphonate-complexed hydroxyapatite implants.. https://doi.org/10.1902/jop.2000.71.2.279

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗