Interactive 3-D virtual colonoscopy system.

Abstract

We describe a low-cost three-dimensional (3-D) virtual colonoscopy system that is a noninvasive technique for examining the entire colon and can assist physicians in detecting polyps inside the colon. Using the helical CT data and proposed techniques, we can three-dimensionally reconstruct and visualize the inner surface of the colon. We generate high resolution of video views of the colon interior structures as if the viewer's eyes were inside the colon. The physicians can virtually navigate inside the colon in two different modes: interactive and automatic navigation, respectively. For automatic navigation, the flythrough path is determined a priori using the 3-D thinning and two-pass tracking schemes. The whole colon is spatially subdivided into several cells, and only potentially visible cells are taken into account during rendering. To further improve rendering efficiency, potentially visible cells are rendered at different levels of detail. Additionally, a chain of bounding volume in each cell is used to avoid penetrating through the colon during navigation. In comparison with previous work, the proposed system can efficiently accomplish required preprocessing tasks and afford adequate rendering speeds on a low-cost PC system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Y Lee, P H Lin, C H Lin, Y N Sun, X Z Lin. 1999. Interactive 3-D virtual colonoscopy system.. https://doi.org/10.1109/4233.767089

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simultaneous determination of hydrocodone and hydromorphone in human plasma by liquid chromatography with tandem mass spectrometric detection.

A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the simultaneous analysis of hydrocodone (HYC) and its metabolite hydromorphone (HYM) in human plasma. A robotic liquid handler and a 96-channel liquid handling workstation were used to aliquot samples, to add internal standard (I.S.), and to extract analytes of interest. A 96-well mixed-mode solid-phase cartridge plate was used to extract the analytes and I.S. The chromatographic separation was on a silica column (50 x 3 mm, 5-microm) with a mobile phase consisting of acetonitrile, water and trifluoroacetic acid (TFA) (92:8:0.01, v/v). The run time for each injection was 2.5 min with the retention times of approximately 2.1 and 2.2 min for HYC and HYM, respectively. The tandem mass spectrometric detection was by monitoring singly charged precursor-->product ion transition 300-->199 (m/z) for HYC, and 28-->185 (m/z) for HYM. The validated calibration curve range was 0.100-100 ng/ml, based on a plasma volume of 0.3 ml. The correlation coefficients were greater than or equal to 0.9996 for both HYC and HYM. The low limit of quantitation (LLOQ) was 0.100 ng/ml for both HYC and HYM with signal-to-noise ratio (S/N) of 50 and 10. respectively. The deuterated analytes, used as internal standards, were monitored at mass transitions 303-->199 (m/z) for HYC-d3 and 289-->185 (m/z) for HYM-d3. The inter-day (n= 17) precision of the quality control (QC) samples were < or = 3.5% RSD (relative standard deviation) for HYC and < or = 4.7% RSD for HYM, respectively. The inter-day accuracy of the QC samples were < or = 2.1% RE (relative error) for HYC and < or = 1.8% RE for HYM. The intra-day (n=6) precision and accuracy of the QC samples were < or = 2.6% RSD and < or = 3.0% RE for HYC, and < or = 4.7% RSD and < or = 2.4% RE for HYM. There was no significant deviation from the nominal values after a 5-fold dilution of high concentration QC samples by blank matrix. The QC samples were stable when kept at room temperature for 24-h or experienced three freeze-thaw cycles. The extraction recoveries were 86% for HYC and 78% for HYM. No detectable carryover was observed when a blank sample was injected immediately after a 2500 ng/ml sample that was 25-fold more concentrated than the upper limit of quantitation (ULOQ).

Automation↗

Direct detection of isotopically labeled metabolites bound to a protein microarray using a charge-coupled device.

A charge-coupled device (CCD) was used to quantitatively detect isotope-labeled ligands bound to a protein microarray. Protein microarrays with protein dots, 10-50 microm in diameter, were fabricated on an aluminized Mylar film using an electrospray deposition technique. Proteins in dots were immobilized by cross-linking in glutaraldehyde vapor. After contact with solutions of isotope-labeled metabolites, the protein microarrays were washed, dried and placed face down onto the surface of a standard B/W video CCD chip with the protective window removed. We show here that such a simple inexpensive CCD detector can be used to quantify distribution of 14C and other radioactive isotopes on microarrays.

Automation↗