PubMed Health⌕ Search

PubMed · 10719696

Real-time three-dimensional motion analysis for patient positioning verification.

Abstract

BACKGROUND AND PURPOSE: This paper describes the technology and methods involved in a system for automatically checking the position of patients at radiotherapy units. This is proposed for improving the accuracy in the irradiation geometrical set-up, which is a crucial factor in radiotherapy quality control. MATERIALS AND METHODS: The system is based on real-time opto-electronics and close-range photogrammetry and detects multiple passive markers placed on selected patient skin landmarks. Patient alignment and position monitoring is carried out by comparing the current three-dimensional positions of the markers with those of an initial reference position acquired during the simulation procedure and/or the first irradiation session. The system was used to measure the accuracy of conventional laser centering techniques for patient repositioning. Inaccuracies due to breathing and random movements were also taken into account. Professional technicians were asked to reposition three volunteer subjects carefully using a traditional laser centering procedure. RESULTS: The results revealed significant repositioning errors even in highly controlled conditions, affecting particularly body areas relatively far from the skin reference points used for laser alignment. CONCLUSIONS: The outcome of the experimental application of this technology confirms its potential as a tool for patient repositioning and automatic detection of any errors caused by breathing or other unpredictable movements. The real-time feedback on the patient's position given by the system provides operators with appropriate visual indices and allows them to take suitable countermeasures in case of significant failures. In addition, the use of the system output for automatic position control is envisaged.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Baroni, G Ferrigno, R Orecchia, A Pedotti. 2000. Real-time three-dimensional motion analysis for patient positioning verification.. https://doi.org/10.1016/s0167-8140(99)00166-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗