Errors in interpreting the pretransfusion bedside compatibility test: an experimental study.

Abstract

BACKGROUND AND OBJECTIVE: Analysis of reports of incidents, involving ABO incompatibility suggests that the main problem is poor interpretation of the pretransfusion bedside compatibility test (PBCT). We studied sources of error as experienced by nurses as to the blood groups of donor blood and of the recipient. MATERIALS AND METHODS: According to their seniority in the profession and on the ward, 48 nurses were randomly selected from four transfusion sectors of the University Hospital of Grenoble, France. Each nurse interpreted 24 photos of PBCTs, including some with procedural irregularities, and was asked to assess the compatibility of the blood types of the donor and the recipient. At random, half the nurses were provided with a diagram to facilitate interpretation. RESULTS: The overall frequency of errors was 39.8%. Errors were fewer when the tests were interpreted as compatible (7.3%) or incompatible (6.3%), and when the nurse had been in the profession between 3 and 5 years and in the ward less than 3 years (25.5%), or worked in hematology (34.7%) or anesthesia (36.5%). Use of the diagram limited the number of errors, provided the test was interpretable (22.2%). CONCLUSION: PBCTs cannot be considered a valid safety procedure. We need other, more effective methods to reduce the risk of incompatibility accidents.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P P Dujardin, L R Salmi, P Ingrand. 2000. Errors in interpreting the pretransfusion bedside compatibility test: an experimental study.. https://doi.org/10.1159/000031147

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

ABO-incompatible heart transplantation in infants.

BACKGROUND: Transplantation of hearts from ABO-incompatible donors is contraindicated because of the risk of hyperacute rejection mediated by preformed antibodies in the recipient to blood-group antigens of the donor. This contraindication may not apply to newborn infants, who do not yet produce antibodies to T-cell-independent antigens, including the major blood-group antigens. METHODS: We studied 10 infants 4 hours to 14 months old (median, 2 months) who had congenital heart disease or cardiomyopathy and who received heart transplants from donors of incompatible blood type between 1996 and 2000. Serum isohemagglutinin titers were measured before and after transplantation. Plasma exchange was performed during cardiopulmonary bypass; no other procedures for the removal of antibodies were used. Standard immunosuppressive therapy was given, and rejection was monitored by means of endomyocardial biopsy. The results were compared with those in 10 infants who received heart transplants from ABO-compatible donors. RESULTS: The overall survival rate among the 10 recipients with ABO-incompatible donors was 80 percent, with 2 early deaths due to causes presumed to be unrelated to ABO incompatibility. The duration of follow-up ranged from 11 months to 4.6 years. Two infants had serum antibodies to antigens of the donor's blood group before transplantation. No hyperacute rejection occurred; mild humoral rejection was noted at autopsy in one of the infants with antibodies. No morbidity attributable to ABO incompatibility has been observed. Despite the eventual development of antibodies to antigens of the donor's blood group in two infants, no damage to the graft has occurred. Because of the use of ABO-incompatible donors, the mortality rate among infants on the waiting list declined from 58 percent to 7 percent. CONCLUSIONS: ABO-incompatible heart transplantation can be performed safely during infancy before the onset of isohemagglutinin production; this technique thus contributes to a marked reduction in mortality among infants on the waiting list.

ABO Blood-Group System↗