Osteodensitometry in uncemented total hip arthroplasty using computertomography.

Abstract

The aim of this investigation was to evaluate a new method developed for the measurement of bone mineral density and bone remodelling phenomena after total hip arthroplasty using computer tomography. Computertomography is a radiological technique to examine bone structures in high resolution. Using an extended scale it is possible to investigate bone scans and implants with fewer metal artifacts. For osteodensitometry measurement a special software (IMPact HIP) for the analysis of the data was used. The measured parameters were the overall bone mineral density (mg Calcium-Hydroxyapatite/ml) and the cortical bone structure. A standard scan mode enable to compare the computertomography scans at follow-up. Nineteen total hip arthroplasty patients (20 hips) with a mean age of 58 years (31-70) were operated on using an uncemented titanium alloy stem with a tapered design. The periprosthetic bone was assessed using computertomography-assisted osteodensitometry two weeks and one year after surgery. We observed a decrease of the overall bone mineral density (15%) and of the cortical bone structure (20%) one year after insertion of the stem in the proximal part of the femur. The area corresponds to the Gruen zones 1 and 7. On the other hand, a decrease of mineral density of 5% for the overall bone and of 3% for the cortical bone was found at the level of the tip of the stem, which corresponds to the Gruen zones 3, 4 and 5. Computertomography-assisted osteodensitometry allows to investigate the bone remodelling after total hip arthroplasty by separating the analysis of the overall bone mineral density and of the cortical structure. The present method is a reliable tool for quality-control in total hip arthroplasty.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Schmidt, J Freund, H Hirschfelder, R P Pitto. 2000. Osteodensitometry in uncemented total hip arthroplasty using computertomography.. https://doi.org/10.1515/bmte.2000.45.3.70

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗