PubMed Health⌕ Search

PubMed · 10765446

Adaptive spatial sampling of contaminated soil.

Abstract

Suppose that a residential neighborhood may have been contaminated by a nearby abandoned hazardous waste site. The suspected contamination consists of elevated soil concentrations of chemicals that are also found in the absence of site-related contamination. How should a risk manager decide which residential properties to sample and which ones to clean? This paper introduces an adaptive spatial sampling approach which uses initial observations to guide subsequent search. Unlike some recent model-based spatial data analysis methods, it does not require any specific statistical model for the spatial distribution of hazards, but instead constructs an increasingly accurate nonparametric approximation to it as sampling proceeds. Possible cost-effective sampling and cleanup decision rules are described by decision parameters such as the number of randomly selected locations used to initialize the process, the number of highest-concentration locations searched around, the number of samples taken at each location, a stopping rule, and a remediation action threshold. These decision parameters are optimized by simulating the performance of each decision rule. The simulation is performed using the data collected so far to imput multiple probable values of unknown soil concentration distributions during each simulation run. This optimized adaptive spatial sampling technique has been applied to real data using error probabilities for wrongly cleaning or wrongly failing to clean each location (compared to the action that would be taken if perfect information were available) as evaluation criteria. It provides a practical approach for quantifying trade-offs between these different types of errors and expected cost. It also identifies strategies that are undominated with respect to all of these criteria.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L A Cox. 1999. Adaptive spatial sampling of contaminated soil.. https://doi.org/10.1023/a%3A1007022409290

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Managing hazardous waste in the laboratory.

This article offers an introduction to the federal U.S. Environmental Protection Agency (EPA) regulations as they relate to hazardous wastes generated by clinical and anatomic pathology laboratories. Traditionally, the EPA has targeted "heavy" industries such as manufacturing for compliance auditing, but it recently turned an eye toward health-care facilities since they are identified as important sources of hazardous waste generation. Enforcement of EPA regulations within health-care facilities presents the challenge of a new labyrinth of definitions, rules, and compliance methods for laboratorians who have already made it through other regulatory agency mazes, including the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) standards, the College of American Pathologists (CAP) checklists, and the Occupational Safety and Health Administration (OSHA) standards.

Hazardous Waste↗

Test method selection, validation against field data, and predictive modelling for impact evaluation of stabilised waste disposal.

In setting criteria for landfill classes in Annex II of the EU Landfill Directive, it proved to be impossible to derive criteria for stabilised monolithic waste due to the lack of information on release and release controlling factors in stabilised waste monofills. In this study, we present a scientific basis, which enables a realistic description of the environmental impact of stabilised waste landfills. The work in progress involves laboratory testing of different stabilisation recipes, pilot scale studies on site and evaluation of field leachate from a full-scale stabilisation landfill. We found that the pHs in run-off and in percolate water from the pilot experiment are both around neutral. The neutral pH in run-off is apparently caused by the rapid atmospheric carbonation of those alkaline constituents that are released. The soil, used as a liner protection layer, controls the release to the subsurface below the landfill. This soil layer buffers pH and binds metals. The modelling results show that the chemistry is understood rather well. Differences between predicted and actual leaching might then be attributed to discrepancies in the description of sorption processes, complexation to organic matter and/or kinetic effects in the leaching tests. We conclude that this approach resulted in a new scientific basis for environmental impact assessment of stabilised waste landfills. The integrated approach has already resulted in a number of very valuable observations, which can be used to develop a sustainable landfill for monolithic waste and to provide guidance for the management of waste to be stabilised (e.g. improved waste mix design).

Hazardous Waste↗

Formation of cinnabar--estimation of favourable conditions in a proposed Swedish repository.

A deep repository for permanent storage of mercury will be designed and built in Sweden. The preferred chemical state for mercury in such a repository would be the sulphide HgS (cinnabar), which is a highly insoluble and the dominating natural mercury mineral. The possible formation of HgS from HgO or Hg(0) by reaction with a sulphur source (S, FeS or FeS(2)) is discussed from thermodynamic considerations, and pe-pH-diagrams are constructed by using the computer code MEDUSA to illustrate under which conditions HgS would dominate. Calculations of the speciation (PHREEQE) under varying conditions (S/Hg-ratios, presence of chloride) are given. Long-term laboratory experiments are performed, where the formation of HgS from the basic components is demonstrated (after mixing under various conditions and storage at room temperature for up to 3 years). The feasibility of HgS-formation with time in a geologic repository under conditions representative of deep granitic bedrock (calcium-bicarbonate buffered to pH 7-8.5) is discussed, as well as effects of alkaline conditions (concrete environment, pH 10.5-12.5). Formation of soluble polysulphides is not expected as long as the S/Hg mole ratio is within 1-1.3 and pH is below 10.5-11. Concrete should be used with caution. Suitable ballast materials could be introduced that would reduce porewater-pH that otherwise would be above 12.

Hazardous Waste↗