Ultraviolet light hazards from transilluminators.

Abstract

Ultraviolet (UV) light boxes ("transilluminators") are commonly used in molecular biology laboratories for visualizing ethidium bromide-intercalated nucleic acids separated under electric current in electrophoretic gels. These devices typically have peak outputs at 254 or 312 nm, well within the UV-C and -B regions that are biologically active and capable of damaging skin. Field evaluations of laboratory transilluminators under actual conditions of use indicate that the UV light emitted from transilluminators is an identifiable and potentially significant occupational hazard for many laboratory workers, as is the high frequency of workstation surface contamination with ethidium bromide, a known mutagen. Fortunately, these hazards can be relatively easily controlled through worker training and the regular use of basic personal protective equipment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R C Klein. 2000. Ultraviolet light hazards from transilluminators.. https://doi.org/10.1097/00004032-200005001-00003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗