PubMed Health⌕ Search

PubMed · 10799444

Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system. The NIAID DAIDS New Technologies Evaluation Group.

Abstract

New analytic methods that permit absolute CD4 and CD8 T-cell determinations to be performed entirely on the flow cytometer have the potential for improving assay precision and accuracy. In a multisite trial, we compared two different single-platform assay methods with a predicate two-color assay in which the absolute lymphocyte count was derived by conventional hematology. A two-color method employing lymphocyte light scatter gating and Beckman Coulter Flow-Count fluorospheres for absolute counting produced within-laboratory precision equivalent to that of the two-color predicate method, as measured by coefficient of variation of replicate measurements. The fully automated Beckman Coulter tetraONE System four-color assay employing CD45 lymphocyte gating, automated analysis, and absolute counting by fluorospheres resulted in a small but significant improvement in the within-laboratory precision of CD4 and CD8 cell counts and percentages suggesting that the CD45 lymphocyte gating and automated analysis might have contributed to the improved performance. Both the two-color method employing Flow-Count fluorospheres and the four-color tetraONE System provided significant and substantial improvements in between-laboratory precision of absolute counts. In some laboratories, absolute counts obtained by the single-platform methods showed small but consistent differences relative to the predicate method. Comparison of each laboratory's absolute counts with the five-laboratory median value suggested that these differences resulted from a bias in the absolute lymphocyte count obtained from the hematology instrument in some laboratories. These results demonstrate the potential for single-platform assay methods to improve within-laboratory and between-laboratory precision of CD4 and CD8 T-cell determinations compared with conventional assay methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K A Reimann, M R O'Gorman, J Spritzler, C L Wilkening, D E Sabath, K Helm, D E Campbell. 2000. Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system. The NIAID DAIDS New Technologies Evaluation Group.. https://doi.org/10.1128/cdli.7.3.344-351.2000

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune regulation of T lymphocyte by a newly characterized human umbilical cord blood stem cell.

Previous work identified a novel type of stem cell from human umbilical cord blood, designated cord blood-stem cells (CB-SC). To further evaluate their immune characteristics, we cocultured CB-SC with allogeneic peripheral blood lymphocytes in the presence of phytohaemagglutinin (PHA) or interleukin-2 (IL-2). Results showed that CB-SC could significantly inhibit lymphocyte proliferation and reduce tyrosine phosphorylation of STAT5 in both PHA- and IL-2-stimulated lymphocytes, along with the regulation on the phenotypes of CD4+ and CD8+ T cells. Additionally, CB-SC also suppressed the proliferation of IL-2-stimulated CD4+CD25+ regulatory T cells. Mechanism studies revealed that programmed death receptor-1 ligand 1 (PD-L1) expressed on CB-SC membrane, together with a soluble factor nitric oxide (NO) released by PHA-stimulated CB-SC, not prostaglandin E2 (PGE2) and transforming growth factor-beta1 (TGF-beta1), mainly contributed to the T cell suppression induced by CB-SC, as demonstrated by blocking experiments with a nitric oxide synthase inhibitor (Nomega-nitro-l-arginine, l-NNA) and a neutralizing antibody to PD-L1. Our findings may advance our understanding of the immunobiology of stem cells and facilitate the therapeutic application of cord blood stem cells.

CD4-CD8 Ratio↗

Tumour lymphocytic infiltrate and recurrence of hepatocellular carcinoma following liver transplantation.

BACKGROUND/AIMS: Liver transplantation is an effective treatment for highly selected patients with hepatocellular carcinoma (HCC), but tumour recurrence remains an important cause of mortality. There are few data on the relation between the recurrence of HCC and lymphocytic infiltration following liver transplantation. METHODS: The tumour CD4+, CD8+, CD25+ and Foxp3+ lymphocyte infiltrate was assessed by immunohistochemistry in explant tissue of 69 patients who underwent liver transplantation for HCC between 1985 and 2001. The data were analysed according to HCC recurrence and factors known to be associated with outcome. RESULTS: Tumour size (Hazard ratio (95% CI: 1.19 (1.02, 1.39), P = 0.03)), vascular invasion (P = 0.02), lymphocyte infiltration (P = 0.02) and CD4:CD8 ratio (P = 0.001) were identified as significant univariate predictors of tumour recurrence. On multivariate analysis CD4:8 ratio (P = 0.001), vascular invasion (P = 0.01), tumour size (P = 0.06) and reduced lymphocyte infiltration (P = 0.03) were significant independent predictors of recurrence. The presence of Foxp3+ T-lymphocytes was not predictive of recurrence, but was associated with vascular invasion (FE = 9.02, P = 0.04). CONCLUSIONS: The data support the hypothesis that immune responses are important in HCC and that the phenotype of infiltrating lymphocytes is informative regarding prognosis.

CD4-CD8 Ratio↗