Scaled clips for aneurysm surgery: technical note.

Abstract

OBJECTIVE: The tips of clip blades are often invisible during operations on large, deep, or posteriorly projecting aneurysms. To overcome this problem, we sought to develop a series of scaled clips. METHODS: We made scaled clips modified from Yaşargil titanium clips. The blades of the new clips are scaled every 5 mm from the tips with alternating colors. We have added six new types of straight scaled clips. RESULTS: To date, we have performed approximately 40 aneurysm clippings using the new scaled clips and have confirmed their usefulness. CONCLUSION: Scaling on the blades helps confirm accurate placement of a clip, even during operations for large, deep, or posteriorly projecting aneurysms, in which blade tips are often invisible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Mizutani. 2000. Scaled clips for aneurysm surgery: technical note.. https://doi.org/10.1097/00006123-200005000-00046

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Challenges of short magnet design.

The desire to improve patient comfort and acceptance of high field magnetic resonance imaging (MRI) systems results in new approaches to magnet and other critical MRI component design. One such approach, based upon an anatomical field of view analysis, is presented in this paper. The approach is utilized to define imaging volume requirements for short, high field, solenoid magnet designs that maintain whole body imaging capability. A short magnet design with excellent magnetic field homogeneity is presented accordingly. Combined with a novel flared gradient coil the overall system achieves improvements in openness.

Equipment Design↗

An application of permeable reactive barrier technology to petroleum hydrocarbon contaminated groundwater.

A funnel and gate permeable reactive barrier was designed and built to treat groundwater contaminated with dissolved phase toluene. ethyl benzene. and xylene and n-alkanes in the C6-C36 fraction range. Removal efficienicies for the funnel and gate system varied from 63% to 96% for the monocyclic aromatic hydrocarbons. Average removal efficiencies for C6-C9, C10-C14, and C15-C28 fraction ranges were 69.2%, 77.6% and 79.5%. respectively. The lowest average removal efficiencies were 54% for the C29-C36 n-alkane fraction. The overall average removal efficiency for the funnel and gate system towards petroleum hydrocarbons present in the groundwater was 72% during the 10 month period over which the data were collected, and has allowed relevant water quality objectives to be met.

Equipment Design↗

Ex vivo testing of a temperature- and pressure-controlled amnio-irrigator for fetoscopic surgery.

BACKGROUND: Currently, amnioinfusion fluids used in operative fetoscopy usually are preheated to body temperature. As the complexity of procedures increases, purposed designed devices should be designed that allow control of pressure and temperature during amnioinfusion or amnioexchange. In the current study, a prototype amnio-irrigator and fluid heater were evaluated. METHODS: The medical fluid heater heats fluid by conduction up to 37 degrees C. The maximum irrigation pressure and flow rates can be preset. Actual irrigation pressure (0 to 30 mm Hg) and flow rate (0 to 300 mL/min) can be read on the front panel. A series of ex vivo experiments were set up to determine the relationship between the flow rate (FR) and lumen of the instruments as well as the maximum flow rate (MFR) with and without the pressure control. Further, the relationship between FR and the irrigation pressure (IP) was determined. In an artificial pseudoamniotic sac the relationship between FR and change in temperature was measured, with and without the use of the medical fluid heater. RESULTS: When the IP was limited to 24 mm Hg, FR and pressure were correlated (r = 0.34; P <.001). The larger the functional lumen of the fetoscopic instrumentation, the higher the flow (r = 0.43; P <.001) and the lower the increase in IP (r = -0.47; P <.001). A quadratic relation between flow and temperature was observed both for preheated fluid as when using the fluid heater (r(2) = 0.71 and r(2) = 0.88; P <.001). However, at low flow rates, a thermal decrease of over 3 degrees C was observed when the fluid heater was not used. CONCLUSIONS: The current study quantifies an expected relationship between the diameter of the irrigation channel and achievable flow rates. It also shows that a medical fluid heater is needed when strict control of temperature would be desired.

Equipment Design↗