PubMed Health⌕ Search

PubMed · 10840465

Changes in urine macromolecular composition during processing.

Abstract

PURPOSE: To determine the urinary crystallization inhibitory activity, urine is generally centrifuged and/or filtered. These preparative procedures may result in a total or partial removal of many macromolecular constituents implicated in crystallization. The main purpose of this study was to investigate the changes in urinary macromolecular composition following centrifugation and filtration. MATERIALS AND METHODS: Twenty-four hour urine samples were collected from human volunteers. Each was divided into 4 aliquots; one was filtered, the other was centrifuged, another was centrifuged and filtered. The control sample was neither filtered nor centrifuged. Total protein and lipid contents of each sample were determined. Proteins were analyzed using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Western blot analysis was performed using antibodies against osteopontin (OPN), prothrombin (PT) related proteins, inter-alpha-inhibitor (IalphaI) related proteins, Tamm-Horsfall protein (THP), and albumin (ALB). The effect of processing on incorporation of urinary proteins in crystal matrices was also examined. Calcium oxalate crystals were produced in processed and unprocessed urine samples by the addition of sodium oxalate. Crystals were harvested, de-mineralized and their proteins analyzed by SDS-PAGE and Western blotting. RESULTS: Processing reduced the amounts of both proteins and lipids in the urine. Previously we identified phospholipids in the matrix of calcium oxalate crystals as well as the filtrate and retentate removed during filtration and centrifugation. Phospholipids have a high affinity for calcium-containing crystals. In the case of proteins, those with high molecular weights appeared to be clearly affected by filtration and centrifugation. Processing also appeared to influence the incorporation of proteins in the crystals. The matrix of crystals produced in processed urine contained less THP than those made in unprocessed urine, apparently a result of the loss of this higher molecular weight protein during processing. Incorporation of PT-related proteins, particularly fragment 1, was increased. CONCLUSIONS: We propose that selective inclusion of macromolecules is a result of an increase in available binding sites on crystal surfaces because of the removal of certain calcium binding substances such as phospholipids and proteins. Removal of larger macromolecules from the milieu may also provide a better access to the crystal surfaces.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Maslamani, P A Glenton, S R Khan. 2000. Changes in urine macromolecular composition during processing.. https://pubmed.ncbi.nlm.nih.gov/10840465/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of flow patterns on chromatographic efficiency in centrifugal partition chromatography.

Visualization of flow patterns in centrifugal partition chromatography (CPC) was performed with an asynchronous camera and a stroboscope triggered by the CPC rotor, allowing a channel to be selected and observed regardless of rotational speed. Three main types of flow states were noted as a function of rotational speed and flow-rate: jets stuck along channel walls, broken jets and atomization. Our observations emphasize the importance of Coriolis force on flow shape. Chromatographic efficiency was related to the dispersion of the mobile phase in the stationary phase.

Centrifugation↗

Improvement purification of sulfated oligofucan by ion-exchange displacement centrifugal partition chromatography.

Centrifugal partition chromatography in ion-exchange displacement mode was used to fractionate mixtures of sulfated oligofucans obtained by partial depolymerization of brown seaweed fucoidans. Diluted (10%, v/v) protonated LA2 (a lipophilic secondary amine) is used as a weak exchanger. In an attempt to improve this method, several solvents (methyl isobutyl ketone, methyl tert.-butyl ether, BuOH) were tested to dissolve LA2H+. MtBE produced less bleeding than MiBK, whereas BuOH proved unsuitable. The sample injected needs to be highly diluted in water to ensure participation in the chromatographic process. A comparison of data (NMR, composition, molecular mass) indicated the homogeneity of the fractions obtained as well as the differences between them.

Centrifugation↗

Liquid-based cervical-cell collection with brushes and wooden spatulas: a comparison of 100 conventional smears from high-risk women to liquid-fixed cytocentrifuge slides, demonstrating a cost-effective, alternative monolayer slide preparation method.

Our purpose was to demonstrate that 17.5-mm liquid-based cytocentrifuge circle-slides made using a Hettich (Andreas Hettich Co., Tuttlingen, Germany) cytocentrifuge are at least as efficacious as conventional smears for detecting cervical abnormalities. One hundred conventional smears were collected with cytobrushes and wooden spatulas from high-risk women. Both devices were then placed into CytoRich Red (AutoCyte, Inc., Burlington, NC). Cells were concentrated from CytoRich Red by centrifugation and suspended in CytoRich Yellow. Two 17.5-mm circle-slides were produced, compared to each other in order to test reproducibility of diagnoses between slides, and compared to conventional slides. Sixty-five normals, three ASCUS, three LSIL, and two HSIL matched. Overall, cytocentrifugation yielded 27 additional findings among 25 cases. Also, it downgraded one conventional ASCUS to normal (immature metaplasia and chronic inflammation) and one conventional HSIL to normal (transitional cell metaplasia). Cytocentrifugation of 14 conventional normals afforded four ASCUS and 10 LSIL. Cytocentrifugation of 11 conventional ASCUS afforded nine LSIL and two HSIL (one with AIS). One HSIL + AIS was found with a conventional HSIL. Cytobrushes and wooden spatulas can be used to collect material for liquid-based cervico-vaginal cytology if they are placed into CytoRich Red. Hettich cytocentrifuge slides were more reliable than conventional smears in presenting well-dispersed, sharply imaged cells, affording greater diagnostic sensitivity and certainty. Compared to previous split-sample studies, three different outcomes were noted: 1) the endocervical component was consistently well-represented; 2) AIS was seen more often in liquid-based slides; and 3) the liquid-based slide did not underdiagnose its conventional companion. The liquid-based preparations downgraded one ASCUS to normal and one conventional HSIL to transitional-cell metaplasia. Histology correlation of these two cases agreed with the liquid-based cytology diagnoses, which validates their specificity. These improvements are ascribed to differences in fixation and processing. The low cost, ease of operation, and reusable chambers of the Hettich cytocentrifuge make it a cost-effective liquid-based cytology instrument, especially for small to intermediate-size laboratories. The claims that this paper makes must be proven by additional studies, and test implementation needs to be scrutinized by appropriate regulatory agencies whose standards may vary from country to country. Diagn. Cytopathol. 2000;22:86-91.

Centrifugation↗