PubMed Health⌕ Search

PubMed · 10842953

Sampling duration calculations.

Abstract

Routine air quality monitoring produces filter samples that, when analyzed, yield the total amount of the aerosol present in the volume of air drawn by the pump in the monitoring device during the given sampling period. From this we obtain an average concentration of the aerosol for the given duration. The samples are therefore really aggregate samples. A natural question then is "what is the effect of the duration of aggregation on the accuracy and precision of the estimate of the quantity of interest?" The answer depends on a number of factors, such as the quantity that is being estimated: a mean, or an extreme value, or some other quantity; the nature of the measurement error--additive versus multiplicative; the costs of laboratory analyses, and so on. In this paper, we investigate these issues when the interest is in estimating the mean concentration of a specified aerosol species over a fixed time period. In particular, we propose a method for determining a sampling duration that will yield the "best estimate" of the mean concentration for a given cost whenever appropriate statistical assumptions hold.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Iyer, P Patterson, W C Malm. 2000. Sampling duration calculations.. https://doi.org/10.1080/10473289.2000.10464118

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An integrated multiscale air quality modelling framework for industrial park pollution: Linking local emissions to regional transport.

Capturing the spatiotemporal distribution of pollutants in industrial parks remains challenging for regional air quality models because of their coarse resolution (3 km), resulting in uncertainties in local emission quantification. To address this, we developed the Integrated Multiscale Air Quality Modelling System for Industry (IAQMS-Industry), coupling the regional Nested Air Quality Prediction Modelling System (NAQPMS) with a city-scale chemical transport model. This framework integrates point-source locations and Gaussian plume dispersion to simulate particulate matter with a diameter smaller than 2.5 micrometres (PM2.5) at 100 m resolution. Applied to the Beijing Yi Zhuang and Tangshan industrial parks and evaluated against observations. The coupled model achieved a normalized mean bias (NMB) ranging from 3.1 % to 6.2 %, improving upon NAQPMS (-16.9 % to -7.7 %). Spatial analysis revealed that coarse regional grids underestimated the PM2.5​ concentrations at industrial sites by smoothing gradients, whereas IAQMS-Industry successfully resolved spatial patterns. Industrial point emissions accounted for 22.9 %-26.4 % of PM2.5 in the coupled model, which was significantly greater than the regional model estimates of 1.6 %-13.7 %. These findings indicate that regional models overestimate pollutant dispersion processes in industrial parks while underestimating local industrial impacts. By explicitly resolving point-source dynamics and linking them to regional transport, IAQMS-Industry provides a robust tool for designing targeted emission controls in industrial cities and balancing local air quality improvements with minimized regional pollution outflow. This study underscores the necessity of multiscale modelling for accurate source apportionment and informed environmental governance in industrial zones.

Air Pollution↗

Daily intake of Se by adult population of Mumbai, India.

The atmospheric Se levels in Mumbai varied between 0.02 and 1.92 ng m(-3) with a mean concentration of 0.21 ng m(-3). The daily intake of Se by the adult population of Mumbai is 61.9 microg day(-1). Differential pulse cathodic stripping voltammetry (DP-CSV) has been used for the determination of Se in air particulate and food samples. The detection limit of Se using DPCSV was found to be 0.05 ng ml(-1). The reliability of estimation was further assessed through the analysis of standard reference materials (SRMs), tuna fish, animal blood, milk powder and fish tissue obtained from IAEA. The frequency distribution of dietary intake levels of selenium for Mumbai adults showed that approximately 61% of the studied population have a dietary intake of 30-90 microg day(-1). Ingestion was found to be the main route of Se exposure for Mumbai adults. The turn over time of Se through blood is 17 days.

Air Pollution↗

Study on CO2 global recycling system.

In order to assist in finding ways to mitigate CO2 emission and to slow the depletion of fossil fuels we have established and evaluated a representative system, which consists of three technologies developed in our laboratory. These technologies were in CO2 recovery, hydrogen production and methanol synthesis and in addition we established the necessary supporting systems. Analysis of outline designs of the large scale renewable energy power generation system and this system and energy input for building plant, energy input for running plant has been conducted based on a case using this system for a 1000-MW coal fired power plant, followed by an evaluation of the material balance and energy balance. The results are as follows. Energy efficiency is 34%, the CO2 reduction rate is 41%, the balance ratio of the energy and CO2 of the system is 2.2 and 1.8, respectively, on the assumption that the primary renewable energy is solar thermal power generation, the stationary CO2 emission source is a coal-fired power plant and the generation efficiency of the methanol power plant is 60%. By adopting the system, 3.7 million tons of CO2 can be recovered, approximately 2.7 million tons of methanol can be produced, and 15.4 billion kWh of electricity can be generated per year. Compared to generating all electrical power using only coal, approximately 2.6 million tons of coal per year can be saved and approximately 2.15 million tons of CO2 emission can be reduced. Therefore, it is clearly revealed that this system would be effective to reduce CO2 emissions and to utilize renewable energy.

Air Pollution↗