Accuracy of decrease in blood flow in predicting hemodialysis graft thrombosis.

Abstract

We recently showed that a single low graft blood-flow measurement (Qa) does not accurately predict graft thrombosis. In this study, we prospectively determined whether percentage of decrease in Qa (DeltaQa) or adjustment of Qa for mean arterial pressure (Qa/MAP; Delta(Qa/MAP)) provides greater predictive accuracy than a single Qa. We monitored 83 grafts from 80 patients for thrombosis over periods up to 12 months. Qa (by ultrasound dilution) and MAP were measured monthly during the study. Receiver operating characteristic curves were used to determine whether Qa, DeltaQa, Qa/MAP, or Delta(Qa/MAP) provided the combination of high sensitivity (>80%) and low false-positive rate (FPR; <20%) needed for clinical use. This level of predictive accuracy requires an area under the curve (AUC) of approximately 0.90. We analyzed the four predictors by a number of criteria and found that all AUCs were less than 0.90 and adjustment for MAP reduced the AUC. In predicting thrombosis within 1 month, for example, AUCs for Qa and net DeltaQa (over 3 months) were 0.84 and 0.82, respectively, whereas AUCs for Qa/MAP and net Delta(Qa/MAP) were 0.78 and 0.75, respectively. At a sensitivity of 80%, FPRs for all predictors were at least 30%. Thus, a high sensitivity always required a high FPR. These results show that DeltaQa and adjustment for MAP are not more accurate than a single low Qa in predicting thrombosis. None of these predictors provide enough predictive accuracy to be the sole criterion for clinical decision making. A successful monitoring and intervention program will likely require the inclusion of other predictors that, together with Qa, may provide the needed accuracy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W D Paulson, S J Ram, C G Birk, M Zapczynski, S R Martin, J Work. 2000. Accuracy of decrease in blood flow in predicting hemodialysis graft thrombosis.. https://doi.org/10.1016/s0272-6386(00)70045-x. https://pubmed.health/record/pubmed%3A10845822/accuracy-of-decrease-in-blood-flow-in-predicting-hemodialysis-graft-thrombosis

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Smooth semiparametric receiver operating characteristic curves for continuous diagnostic tests.

We propose a semiparametric kernel distribution function estimator, based on which a new smooth semiparametric estimator of the receiver operating characteristic (ROC) curve is constructed. We derive the asymptotic bias and variance of the newly proposed distribution function estimator and show that it is more efficient than the traditional non-parametric kernel distribution estimator. We also derive the asymptotic bias and variance of our new ROC curve estimator and show that it is more efficient than the smooth non-parametric ROC curve estimator proposed by Zou et al. (Stat. Med. 1997; 16:2143-2156) and Lloyd (J. Am. Stat. Assoc. 1998; 93:1356-1364). For our proposed estimators, we derive data-based methods for bandwidth selection. In addition, we present some results on the analysis of two real data sets. Finally, a simulation study is presented to show that our estimators are better than the non-parametric counterparts in terms of bias, standard error, and mean-square error.

Area Under Curve↗

Redox potential measurement as a rapid method for microbiological testing and its validation for coliform determination.

The redox potential is one of the most complex indicators of the physiological state of microbial cultures and its measurement could be a useful tool for the qualitative and quantitative determination of the microbial contamination. During the bacterial growth, the redox potential of the medium decreases. The shape of the redox potential curve is characteristic on the type of microorganism, and the rate of the change (dE/dt) is proportional to the living cell concentration. Defining the time required to reach a significant change in redox potential as Time to Detection (TTD), similarly to the impedimetric measurements, a strict linear correlation could be established between the TTD and the logarithm of the initial concentration of microorganisms. On the base of this calibration curve, the determination of living cell concentration could be simplified. For the experiments, a computer-controlled multi-channel measuring system and software was developed by the authors. The redox potential measurement method was tested and validated for the determination of coliform bacteria. The results have proved the high efficiency and reliability of the new method.

Area Under Curve↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗