PubMed Health⌕ Search

PubMed · 10847366

A centralized dose calculation system for radiation therapy.

Abstract

Centralization of treatment planning in a radiation therapy department is a realistic strategy to achieve an integrated and quality-controlled planning system, especially for institutions with numerous affiliations. The rapid evolution of computer hardware and software technology makes this a distinct possibility. However, the procedure of three-dimensional treatment planning involves a number of steps, such as: (1) input of patient computed tomography (CT) images and contour information; (2) interactions with local devices such as a film digitizer; and (3) output of beam information to be integrated with the record and verify the system. A full-fledged realization of the web-based centralized three-dimensional treatment planning system will require an extensive commercial development effort. We have developed and incorporated a web-based Timer/Monitor Unit (MU) program as a first step towards the full implementation of a centralized treatment planning system. The software application was developed in JAVA language. It uses the internet server and client technology. With one server that can handle multiple threads, it is a simple process to access the application anywhere on the network with an internet browser. Both the essential data needed for the calculation and the results are stored on the server, which centralizes the maintenance of the software and the storage of patient information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Xiao, J Galvin. 2000. A centralized dose calculation system for radiation therapy.. https://doi.org/10.1007/bf03167628

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗