PubMed Health⌕ Search

PubMed · 10865653

Straw vote.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Ochs. 2000. Straw vote.. https://pubmed.ncbi.nlm.nih.gov/10865653/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On-line preconcentration, ion chromatographic separation and spectrophotometric determination of palladium at trace level.

A new method for the determination of Pd by ion chromatography and spectrophotometric detection has been developed. The technique is based on the separation of palladium as PdCl4(2-) by anion exchange and on the detection, at a wavelength of 407 nm, of metal as PdI4(2-) after a post-column reaction with KI. The column used was an IonPac AS4 with HCl and HClO4 eluents. The eluent concentration and composition of post-column reagent were optimised in order to obtain the best separation and sensitivity for Pd. In order to reduce the detection limit, an on-line preconcentration step, has been optimised. The method, as developed, was suitable for palladium determination within a 300 ng/l D.L. value. The method applied to a BCR reference material (CRM 277, estuarine sediment) gave satisfactory results in agreement with the certified value within a D.L. value of 1.3 microg/l for the real sample.

Anion Exchange Resins↗

Protein loading, elution, and resolution behavior in a novel device that integrates ultrafiltration and chromatographic separation.

Hollow fiber membranes and chromatographic resin beads are commonly employed in a variety of bioseparation processes. A new class of integrated separation devices is being studied in which the shell side of a hollow fiber device is filled with adsorbents/chromatographic resin beads. Such devices and the corresponding separation methods integrate feed broth clarification by the microfiltration/ultrafiltration membrane with bioproduct purification by the shell-side resin beads either as an adsorbent or as beads in elution chromatography. A mathematical model has been developed for the prediction of the chromatographic behavior of such an integrated device. Simulations have been done to study the effects of axial dispersion, feed flow rate, water permeation rate, fiber packing density, and void fraction. Numerical solutions were obtained by solving the governing equations. This model can reasonably describe the concentration profiles as well as the breakthrough and elution behaviors in the integrated device.

Anion Exchange Resins↗

Comparison between mass transfer properties of weak-anion-exchange resins with graft-functionalized polymer layers and traditional ungrafted resins.

Glycidylmethacrylate was grafted to Toyopearl HW-65M and subsequently modified with diethylamine to obtain a weak anion exchanger. The degree of grafting was varied from 11 to 50%. The binding capacity for bovine serum albumin was 11 mg/ml for the lowest degree of grafting and 97 mg/ml for the highest degree of grafting. The maximum binding capacity was observed at 27% degree of grafting. The mass transfer properties of the grafted resins and an ungrafted resin(Toyopearl DEAE 650M) were investigated assuming rectangular isotherms. Simple models for reaction kinetics, pore- and surface diffusion and film diffusion were used to describe the concentration-time data in batch mode. The data were best fitted by a pore diffusion model. The estimated pore diffusion coefficients (D(P)) for bovine serum albumin were fitted by a polynome to the degree of grafting with an maximum value at 27% of D(P) = 1.95-10(-11) m2/s. Compared to published data of other ungrafted resins and to the molecular diffusion coefficient of bovine serum albumin in free solution of D(P) = 5.6 10(-11) m2/s, the diffusion in grafted layers seems to be accelerated. The breakthrough curves for columns packed with various resins showed a decrease in sharpness with increasing degree of grafting which could not be described by a simple pore diffusion model using the calculated transport coefficients from batch mode. The shape of the breakthrough curves could be well described by a combined film and pore diffusion model. For the ungrafted Toyopearl DEAE 650M resin the breakthrough curve is more favorable and the influence of film diffusion to the mass transfer is reduced. It can be concluded that grafting will increase the capacity and the pore diffusion in batch mode but in column operation the grafting layer has a film resistance which plays an important role in the overall mass transfer.

Anion Exchange Resins↗