PubMed Health⌕ Search

PubMed · 10873200

A multicoil array designed for cardiac SMASH imaging.

Abstract

Recently, several partially parallel acquisition (PPA) techniques have been presented which use spatial information inherent in an RF coil array to reconstruct an image from a reduced set of phase encoding steps. PPAs represent a change in paradigm for the RF coil designer since the focus for arrays to be used with PPAs is to optimize the spatial encoding that is provided by the array. One of the first practical implementations of PPA imaging was demonstrated using the SMASH technique. In this study, we present our results from the construction of the first array designed specifically for cardiac SMASH imaging. Additional design criteria are presented for SMASH arrays that are not considered in conventional array design. Using these design criteria, a four-element array was constructed and then tested in SMASH imaging experiments in the heart. This array has been used in all of our initial cardiac and head SMASH studies with good results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M A Griswold, P M Jakob, R R Edelman, D K Sodickson. 2000. A multicoil array designed for cardiac SMASH imaging.. https://doi.org/10.1007/bf02601845

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Amusement park injuries and deaths.

Media coverage of amusement park injuries has increased over the past several years, raising concern that amusement rides may be dangerous. Amusement park fatalities and increases in reported injuries have prompted proposed legislation to regulate the industry. Since 1979, the medical literature has published reports of 4 subdural hematomas, 4 internal carotid artery dissections, 2 vertebral artery dissections, 2 subarachnoid hemorrhages, 1 intraparenchymal hemorrhage, and 1 carotid artery thrombosis with stroke, all related to roller coaster rides. In this article, we review reports of amusement park injuries in the medical literature and Consumer Product Safety Commission data on the overall risk of injury. We also discuss the physics and the physiologic effects of roller coasters that may influence the type and severity of injuries. Although the risk of injury is low, emergency physicians are advised to include participation on thrill rides as part of their history, particularly when evaluating patients presenting with neurologic symptoms.

Biophysical Phenomena↗

High-pressure transformations in xenon hydrates.

A high-pressure investigation of the Xe*H(2)O chemical system was conducted by using diamond-anvil cell techniques combined with in situ Raman spectroscopy, synchrotron x-ray diffraction, and laser heating. Structure I xenon clathrate was observed to be stable up to 1.8 GPa, at which pressure it transforms to a new Xe clathrate phase stable up to 2.5 GPa before breaking down to ice VII plus solid xenon. The bulk modulus and structure of both phases were determined: 9 +/- 1 GPa for Xe clathrate A with structure I (cubic, a = 11.595 +/- 0.003 A, V = 1,558.9 +/- 1.2 A(3) at 1.1 GPa) and 45 +/- 5 GPa for Xe clathrate B (tetragonal, a = 8.320 +/- 0.004 A, c = 10.287 +/- 0.007 A, V = 712.1 +/- 1.2 A(3) at 2.2 GPa). The extended pressure stability field of Xe clathrate structure I (A) and the discovery of a second Xe clathrate (B) above 1.8 GPa have implications for xenon in terrestrial and planetary interiors.

Biophysical Phenomena↗

Definition of the rheological glass transition temperature in association with the concept of iso-free-volume.

Small deformation dynamic oscillation was used to develop an index of physical significance for the rationalisation of the mechanical properties of high co-solute/biopolymer systems during vitrification. The index is based on the combined framework of Williams-Landel-Ferry equation with the free volume theory and is called the 'rheological glass transition temperature, T(g)' thus differentiating it from the empirical calorimetric T(g) used in thermal analysis. The rheological T(g) is located at the conjunction of two distinct molecular processes, namely: free-volume effects in the glass transition region and the predictions of the reaction-rate theory in the glassy state. The method of reduced variables was used to shift the mechanical spectra of shear moduli to composite curves. The temperature dependence of shift factors for all materials was identical provided that they were normalised at suitably different reference temperatures, which reflect iso-free-volume states. The treatment makes free volume the overriding parameter governing the mechanical relaxation times during vitrification of high co-solute/biopolymer systems regardless of physicochemical characteristics. We believe that potential applications resulting from this fundamental work are numerous for the food and pharmaceutical industries.

Biophysical Phenomena↗