PubMed Health⌕ Search

PubMed · 10898813

On Low Voltage Scanning Electron Microscopy and Chemical Microanalysis.

Abstract

The current status and general applicability of scanning electron microscopy (SEM) at low voltages is reviewed for both imaging (low voltage scanning electron microscopy, LVSEM) and chemical microanalysis (low voltage energy-dispersive X-ray spectrometry, LVEDX). With improved instrument performance low beam energies continue to have the expected advantages for the secondary electron imaging of low atomic number (Z) and electrically non-conducting samples. They also provide general improvements in the veracity of surface topographic analysis with conducting samples of all Z and at both low and high magnifications. In new experiments the backscattered electron (BSE) signal retains monotonic Z dependence to low voltages (<1 kV). This is contrary to long standing results in the prior literature and opens up fast chemical mapping with low dose and very high (nm-scale) spatial resolution. Similarly, energy-dispersive X-ray chemical microanalysis of bulk samples is extended to submicron, and in some cases to <0.1 µm, spatial resolution in three dimensions at voltages <5 kV. In favorable cases, such as the analysis of carbon overlayers at 1.5 kV, the thickness sensitivity for surface layers is extended to <2 nm, but the integrity of the sample surface is then of concern. At low beam energies (E(0)) the penetration range into the sample, and hence the X-ray escape path length out of it, is systematically restricted (R = F(E(0)(5/3))), with advantages for the accuracy or elimination of complex analysis-by-analysis matrix corrections for absorption (A) and fluorescence (F). The Z terms become more sensitive to E(0) but they require only one-time calibrations for each element. The new approach is to make the physics of the beam-specimen interactions the primary factor and to design enabling instrumentation accordingly.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E D Boyes. 2000. On Low Voltage Scanning Electron Microscopy and Chemical Microanalysis.. https://doi.org/10.1007/s100050010035

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effectiveness of high-dose versus standard-dose influenza vaccines against hospitalisation according to frailty risk: a prespecified analysis of the randomised trial DANFLU-2.

BACKGROUND: Frailty is a major risk factor for influenza-related complications and can influence vaccine effectiveness. We aimed to assess the relative vaccine effectiveness (rVE) of high-dose (HD-IIV) versus standard-dose inactivated influenza vaccine (SD-IIV) in older adults aged 65 years or older according to frailty risk. METHODS: This study was a prespecified analysis of DANFLU-2, an open-label, individually randomised trial, conducted in Denmark during three consecutive influenza seasons (2022-23, 2023-24, and 2024-25). Adults aged 65 years or older were randomised (1:1) to the HD-IIV or SD-IIV group. The primary endpoint was hospitalisation for influenza or pneumonia. Frailty was defined according to the validated Hospital Frailty Risk Score (HFRS) based on ICD-10 codes within 10 years before randomisation. Participants were stratified into three HFRS categories, namely low (<5 points), intermediate (5-15 points), and high (>15 points) frailty risk. The rVE of HD-IIV versus SD-IIV against the primary endpoint was assessed across prespecified HFRS categories and treating HFRS as a continuous variable. Pearson's chi-square test was used to compare safety events across frailty risk groups and randomisation groups. FINDINGS: Among 332&#x2009;438 randomised participants (mean age 73&#xb7;7 years [SD 5&#xb7;8]; 161&#x2009;538 [48&#xb7;6%] were female), 276&#x2009;173 (83&#xb7;1%) had low frailty risk, 52&#x2009;395 (15&#xb7;8%) had intermediate frailty risk, and 3861 (1&#xb7;2%) had high frailty risk. The primary endpoint of hospitalisation for influenza or pneumonia occurred in 1424 (0&#xb7;5%) of 276&#x2009;173 participants with low frailty risk, 761 (1&#xb7;5%) of 52&#x2009;395 with intermediate frailty risk, and 163 (4&#xb7;2%) of 3861 with high frailty risk (relative risk [RR] for intermediate vs low frailty risk 2&#xb7;8 [95% CI 2&#xb7;6-3&#xb7;1]; RR for high vs low frailty risk 8&#xb7;2 [7&#xb7;0-9&#xb7;6]). HFRS as a continuous variable significantly modified the effect of HD-IIV versus SD-IIV against the primary endpoint with higher rVE estimates with increasing HFRS (pinteraction=0&#xb7;020). The rVE was 0&#xb7;2% (95% CI -10&#xb7;8 to 10&#xb7;2) among those with low frailty risk, 13&#xb7;1% (-0&#xb7;4 to 24&#xb7;8) among those with intermediate frailty risk, and 19&#xb7;9% (-10&#xb7;3 to 42&#xb7;1) among those with high frailty risk. No significant interaction was observed when HFRS was assessed according to the prespecified categorical frailty groups (pinteraction=0&#xb7;17). The proportion of participants with at least one serious adverse event increased across frailty risk groups (13&#x2009;366 [4&#xb7;8%] of 275&#x2009;795 for low frailty risk, 5475 [10&#xb7;5%] of 52&#x2009;315 for intermediate frailty risk, and 777 [20&#xb7;2%] of 3850 for high frailty risk; p<0&#xb7;0001), with similar proportions of serious adverse events in the HD-IIV and SD-IIV groups for each frailty risk group. INTERPRETATION: Among adults aged 65 years or older in Denmark, frailty risk might modify the effects of HD-IIV versus SD-IIV against hospitalisation for influenza or pneumonia, with higher rVE estimates with increasing frailty risk. These findings might support considering high-dose influenza vaccines for frail older adults. However, effect modification was not evident when frailty was assessed using prespecified categorical subgroups, and subgroup-specific estimates were imprecise, with 95% CIs crossing the null. These results should be considered exploratory, warranting further investigation. FUNDING: The DANFLU-2 trial was funded by Sanofi.

Journal Article↗